Filters · 3 active
Manufacturer:
IVT
Inventor
AIRCLASS
(2)
AIRWELL
(38)
ATLANTIC
(27)
AUX
(19)
BOSCH
(75)
BRYANT
(4)
Buderus
(22)
CARRIER
(66)
CIAT
(13)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(16)
DAIKIN
(315)
EQUATION
(3)
FUJI ELECTRIC
(77)
FUJITSU
(167)
Fujitsu Atlantic
(92)
GENERAL
(136)
GREE
(66)
GSS
(2)
HAIER
(263)
HEC
(5)
HEIWA
(5)
HISENSE
(241)
HITACHI
(57)
KAYSUN
(17)
LG
(174)
MIDEA
(362)
MITSUBISHI ELECTRIC
(226)
Mitsubishi Heavy Industries
(74)
NORD
(33)
Nobu
(4)
PANASONIC
(165)
RIELLO
(15)
Rotenso
(0)
SAMSUNG
(117)
THERMOR
(40)
TOSHIBA
(134)
Viessmann
(8)
Vulcano
(6)
WESTPOINT
(15)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
Aero 504 O CN / Aero 504 I CN
Aero 500
|
IVT | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
Aero 503 O CN / Aero 503 I CN
Aero 500
|
IVT | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
Aero 704 O / Aero 704 I
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
Aero 704 O / Aero 704 IB
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
THRVO-12/THRVI-12WFI
Thora
|
Inventor | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
THRVO-09/THRVI-09WFI
Thora
|
Inventor | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.00 | 5.10 | 4.40 | -10° | 2.70 | 2.90 | |
|
ΝECUVO-09/ΝECUVI-09WFI
Neo Eco
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
NPVO-09/NPVI-09WFI
Neo Plus
|
Inventor | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
EQO-09/EQI-09WFI
Econ IQ
|
Inventor | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.70 | 4.30 | -10° | 2.60 | 2.50 | |
|
U7RS-12/V7iDI-12WiFiR
Ducted R32
|
Inventor | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
THRVO-18/THRVI-18WFI
Thora
|
Inventor | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.12 | -10° | 5.00 | 4.20 | |
|
Aero 705 O / Aero 705 I
Aero 700
|
IVT | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
Aero 705 O / Aero 705 IB
Aero 700
|
IVT | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
EQO-12/EQI-12WFI
Econ IQ
|
Inventor | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 3.80 | -10° | 3.50 | 2.60 | |
|
INVO-18/INVI-18WFI
Intellia
|
Inventor | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
EQO-18/EQI-18WFI
Econ IQ
|
Inventor | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.00 | |
|
LEUVO-09/LEUVI-09WFI
Leon
|
Inventor | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
LHUVO-09/LHUVI-09WFI
Leon
|
Inventor | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
LEUVOCP-09/LEUVICP-09WFI
Leon
|
Inventor | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
ΝECUVO-12/ΝECUVI-12WFI
Neo Eco
|
Inventor | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
NPVO-12/NPVI-12WFI
Neo Plus
|
Inventor | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
INVO-09/INVI-09WFI
Intellia
|
Inventor | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
Aero 603-1 O / Aero 603-1 I
Aero 600-1
|
IVT | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
U7RS-09/V7LI-09WiFiR
Console R32
|
Inventor | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
DR2VO-09/DR2VI-09WFI
Dark
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
MFVO-09/MFVI-09WFI
Comfort
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
EMPVO-09/EMPVI-09WFI
Emperor
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
EMPVO(W)-09/EMPVI(W)-09WFI
Emperor
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
Aero 604-1 O / Aero 604-1 I
Aero 600-1
|
IVT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
LEUVO-12/LEUVI-12WFI
Leon
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
LHUVO-12/LHUVI-12WFI
Leon
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
LEUVOCP-12/LEUVICP-12WFI
Leon
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
INVO-12/INVI-12WFI
Intellia
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
DR2VO-12/DR2VI-12WFI
Dark
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
MFVO-12/MFVI-12WFI
Comfort
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
EMPVO-12/EMPVI-12WFI
Emperor
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
EMPVO(W)-12/EMPVI(W)-12WFI
Emperor
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
U7RS-12/V7iCRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7DI-12WiFiR
Ducted R32
|
Inventor | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7CRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
NRO-09/NRI-09WFI
Nura
|
Inventor | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 4.00 | -10° | 2.60 | 2.30 | |
|
FUTO-09/FUTI-09WFI
Futura AI
|
Inventor | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.40 | -10° | 2.70 | 2.40 | |
|
IKUO-09/IKUI-09WFI
Ikura
|
Inventor | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.40 | -10° | 2.70 | 2.40 | |
|
NRO-12/NRI-12WFI
Nura
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
O3MVO32-09F/O3MVI32-09WiFiRF
Omnia 3 (ECO)
|
Inventor | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
AR5VO-12/AR5VI-12WFI
Aria (AR5)
|
Inventor | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.50 | -10° | 3.50 | 2.91 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
FUTO-12/FUTI-12WFI
Futura AI
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
IKUO-12/IKUI-12WFI
Ikura
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
U7RS-18/V7LI-18WiFiR
Console R32
|
Inventor | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 |