Filters · 3 active
Manufacturer:
AIRCLASS
KAYSUN
AIRWELL
(19)
ATLANTIC
(17)
AUX
(11)
BOSCH
(61)
BRYANT
(0)
Buderus
(11)
CARRIER
(45)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(301)
EQUATION
(2)
FUJI ELECTRIC
(62)
FUJITSU
(136)
Fujitsu Atlantic
(74)
GENERAL
(107)
GREE
(40)
GSS
(0)
HAIER
(116)
HEC
(2)
HEIWA
(3)
HISENSE
(124)
HITACHI
(64)
IVT
(8)
Inventor
(28)
LG
(90)
MIDEA
(176)
MITSUBISHI ELECTRIC
(174)
Mitsubishi Heavy Industries
(154)
NORD
(12)
Nobu
(0)
PANASONIC
(173)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(51)
THERMOR
(16)
TOSHIBA
(102)
Viessmann
(2)
Vulcano
(2)
WESTPOINT
(6)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
KAE-26 DR9/KAY-P 26 DR12
SUITE Prodigy PRO
|
KAYSUN | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.65 | -10° | 2.70 | 2.50 | |
|
AITO-09322.MH/AIT-09322.MH
AIT
|
AIRCLASS | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
AITO-12322.MH/AIT-12322.MH
AIT
|
AIRCLASS | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.01 | -25° | 3.50 | 2.60 | |
|
KAE-S 26 DR9/KAY-D 26 DR11
SUITE Onnix 2.0
|
KAYSUN | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.20 | -10° | 2.60 | 2.40 | |
|
KUE-90 DVR13/KPD-90 DR14
ZEN Duct
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
KUE-26 DVR14/KSD-26 DR14-2
Console R32
|
KAYSUN | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
KUE-90 DVR13/KCIS-90 DR14
ZEN Cassette
|
KAYSUN | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
KUE-71 DVR13/KPD-71 DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
KUE-71 DVR13/KPD-71V DR14
ZEN Duct
|
KAYSUN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
KUE-71 DVR14/KCIS-71 DR14
Cassette R32
|
KAYSUN | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
KUE-35 DVR13/KSD-35 DR14-2
ZEN Console
|
KAYSUN | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
KUE-71 DVR13/KPC-71 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
KUE-71 DVR13/KCIS-71 DR14
ZEN Cassette
|
KAYSUN | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
KAE-C 26 DR11/KAY-CF 26 DR12
SUITE Casual
|
KAYSUN | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 |