Filters · 3 active
Manufacturer:
KAYSUN
LG
AIRCLASS
(0)
AIRWELL
(14)
ATLANTIC
(8)
AUX
(0)
BOSCH
(17)
BRYANT
(3)
Buderus
(3)
CARRIER
(42)
CIAT
(18)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(8)
DAIKIN
(201)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(57)
Fujitsu Atlantic
(28)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(185)
HEC
(3)
HEIWA
(0)
HISENSE
(33)
HITACHI
(35)
IVT
(0)
Inventor
(51)
MIDEA
(258)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(99)
NORD
(25)
Nobu
(6)
PANASONIC
(13)
RIELLO
(20)
Rotenso
(7)
SAMSUNG
(45)
THERMOR
(11)
TOSHIBA
(79)
Viessmann
(8)
Vulcano
(4)
WESTPOINT
(0)
YORK
(20)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
KUE-105 DVR13/KPC-105 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
KUE-105 DVR13/KPD-105 DR15
Duct R32
|
KAYSUN | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
KUE-160 DTR14/KPD-160 DR15
Zen
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
KUE-140 DVR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KPD-140 DR15
Zen
|
KAYSUN | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
KUE-160 DTR13/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM48AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM49AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
KUE-105 DVR13/KPD-105 DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
KUE-105 DVR13/KPD-105V DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
UUC1 U40 / UV36F N20
U4
|
LG | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.70 | -10° | 9.50 | 5.50 | |
|
KUE-125 DVR13/KPD-125 DR15
Zen
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
MU5R36 U36A0 / MJ18PC NSK0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.15 | 3.25 | -10° | 9.20 | 6.80 | |
|
KUE-125 DVR13/KPD-125 DR13
Zen
|
KAYSUN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
KUE-125 DVR13/KPD-125 DR14
Zen
|
KAYSUN | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
KUE-105 DTR13/KPD-105 DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
KUE-105 DTR13/KPD-105 DR15
Duct R32
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
KUE-105 DVR13/KCIS-105 DR14
ZEN Cassette
|
KAYSUN | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
UUD1 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
UUD3 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
MU4R27 U24A0 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.19 | 3.50 | -10° | 7.00 | 5.50 | |
|
UUB1 U20 / CM24F N10
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
UUB1 U20 / CM24F N11
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
KUE-140 DTR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
KUE-160 DTR14/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
UUD1 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZBNW60GM3A1
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUB1 U20 / CM24F NA0
UU
|
LG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.41 | -10° | 6.80 | 4.10 | |
|
KUE-160 DTR13/KCIS-160 DR14
Zen
|
KAYSUN | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -10° | 15.30 | 11.90 | |
|
UUD1 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUD3 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
KUE-140 DTR13/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KCIS-140 DR14
Zen
|
KAYSUN | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.58 | -10° | 14.00 | 11.20 | |
|
KUE-140 DTR13/KPD-140 DR13
Zen
|
KAYSUN | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
KUE-140 DTR13/KPD-140 DR14
Zen
|
KAYSUN | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
KUE-105 DTR13/KPC-105 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
KUE-125 DVR13/KCIS-125 DR13
Zen
|
KAYSUN | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
KUE-125 DVR13/KCIS-125 DR14
Zen
|
KAYSUN | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
KUE-160 DTR14/KPV-160 DR14
Zen
|
KAYSUN | Floor standing | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
KUE-160 DTR14/KCIS-160 DR14
Zen
|
KAYSUN | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 |