Filters · 3 active
Manufacturer:
LG
MIDEA
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(0)
AUX
(10)
BOSCH
(15)
BRYANT
(0)
Buderus
(2)
CARRIER
(22)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(230)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(88)
HEC
(0)
HEIWA
(0)
HISENSE
(34)
HITACHI
(41)
IVT
(0)
Inventor
(15)
KAYSUN
(26)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(10)
Nobu
(0)
PANASONIC
(42)
RIELLO
(11)
Rotenso
(3)
SAMSUNG
(23)
THERMOR
(5)
TOSHIBA
(45)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUC1 U40 / UM24FH N20
U4
|
LG | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.30 | 4.28 | -10° | 6.80 | 5.40 | |
|
UUC1 U40 / UM30FH N20
U4
|
LG | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.97 | -10° | 7.90 | 5.40 | |
|
UUB1 U20 / UM18FH N10
UU
|
LG | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.89 | -10° | 5.00 | 4.40 | |
|
UUD1 U30 / UM36FH N30
UU
|
LG | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.20 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36FH N30
UU
|
LG | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.20 | -10° | 9.50 | 9.50 | |
|
MOD30U-30HFN8-QRD1W(GA)/MTJ-30HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-Q1(GA)/MTJ-30HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
MO-30N8-Q-1/MTJ-30NX
Duct R32
|
MIDEA | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-Q1(H)/MTJ-30HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
MOX430U-24HFN8-QRD1W(GA)/MTJ-24HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W/MTJ-24HWFNX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(GA)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MO-24N8-Q-1/MTJU-24NX
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-QRD1W(GA)-GR/MTJ-24HWFNX-QRD1W(GA)-GR
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX430U-24HFN8-Q1(H)/MTJ-24HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
MOX230-12HFN8-QRD0W(GA)/MTJ-12HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MTJU-12HNX
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MTJ-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
M4OA-27HFN8-Q(HRU)/MTJ-09HWFNX-QRD1W(GA)+MTJ-18HWFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.90 | 6.30 | |
|
UUB1 U20 / UM18FH NA0
UU
|
LG | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -10° | 5.00 | 4.40 | |
|
MOX330U-18HFN8-QRD0W(GA)/MTJ-18HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MOX330U-18HFN8-Q(GA)/MTJ-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MO-18N8-Q/MTJU-18NX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
MOX330U-18HFN8-Q(H)/MTJ-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
UUD1 U30 / UM42FH N30
UU
|
LG | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.85 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42FH N30
UU
|
LG | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.85 | -10° | 12.00 | 9.50 | |
|
UUB1 U20 / UL18FH N30
UU
|
LG | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 5.00 | 4.10 | |
|
MOX230-09HFN8-QRD1W(GA)/MTJ-09HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MOX230-09HFN8-Q(GA)/MTJ-09HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MO-09N8-Q/MTJU-09HNX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MOD30U-36HFN8-QRD0W(GA)/MTJ-36HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
MOD30U-36HFN8-Q(GA)/MTJ-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
MO-36N8-Q/MTJ-36NX
Duct R32
|
MIDEA | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
MOD30U-36HFN8-Q(H)/MTJ-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
UUB1 U20 / CM18F N10
UU
|
LG | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.30 | -10° | 5.00 | 4.10 | |
|
UUB1 U20 / CM18F N11
UU
|
LG | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.30 | -10° | 5.00 | 4.10 | |
|
UUD1 U30 / UM48FH N30
UU
|
LG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | 13.40 | 9.50 | ||
|
UUD3 U30 / UM48FH N30
UU
|
LG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 3.71 | 13.40 | 9.50 | ||
|
MOX630U-55HFN8-RRD0W(GA)/MTJ-55HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R(GA)/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MO-55N8-R-1/MTJ-55NX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-RRD0W/MTJI-55HWFNX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-RRD0W(GA)-GR/MTJ-55HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R(H)/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R OUT V1/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-Q(GA)/MTI-30HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MO-30N8-Q/MTI-30HNX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 |