Filters · 3 active
Manufacturer:
MITSUBISHI ELECTRIC
TOSHIBA
AIRCLASS
(2)
AIRWELL
(70)
ATLANTIC
(38)
AUX
(59)
BOSCH
(73)
BRYANT
(6)
Buderus
(28)
CARRIER
(106)
CIAT
(35)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(16)
DAIKIN
(305)
EQUATION
(5)
FUJI ELECTRIC
(113)
FUJITSU
(293)
Fujitsu Atlantic
(143)
GENERAL
(155)
GREE
(71)
GSS
(4)
HAIER
(520)
HEC
(5)
HEIWA
(6)
HISENSE
(270)
HITACHI
(118)
IVT
(3)
Inventor
(135)
KAYSUN
(62)
LG
(265)
MIDEA
(718)
Mitsubishi Heavy Industries
(266)
NORD
(51)
Nobu
(8)
PANASONIC
(155)
RIELLO
(38)
Rotenso
(8)
SAMSUNG
(160)
THERMOR
(56)
Viessmann
(22)
Vulcano
(16)
WESTPOINT
(17)
YORK
(35)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-ZM125VDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.44 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.44 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM140VDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.15 | 5.10 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.15 | 5.10 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 5.09 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.09 | 5.09 | 3.60 | -20° | 13.40 | 10.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401FT-E
SDI
|
TOSHIBA | Floor standing | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.49 | 4.38 | 3.00 | -27° | 12.30 | 9.60 | |
|
RAV-GP1101AT-E/RAV-HM1101KRTP-E
SDI
|
TOSHIBA | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.42 | 3.58 | -27° | 10.00 | 9.20 | |
|
RAV-GP1401AT-E1/RAV-HM1401CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.99 | 4.73 | 3.90 | -27° | 12.50 | 9.60 | |
|
PUZ-ZM71VHA2/PLA-M71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.60 | 3.97 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PLA-M71EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.60 | 3.97 | -20° | 7.10 | 4.70 | |
|
RAV-GP801ATW-E/RAV-HM801SDTY-E
SDI
|
TOSHIBA | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.27 | 3.77 | -27° | 7.10 | 5.10 | |
|
RAV-GM562ATP-E/RAV-HM561UTP-E
DI
|
TOSHIBA | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.62 | 3.90 | -15° | 5.00 | 2.80 | |
|
PUZ-ZM125VDA/PLA-ZM125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.48 | 4.73 | 3.60 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PLA-ZM125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.48 | 4.73 | 3.60 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA/PLA-ZM125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.43 | 4.73 | 3.60 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PLA-ZM125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.43 | 4.73 | 3.60 | -20° | 12.50 | 9.30 | |
|
RAS-13P2AVSG-E/RAS-B13N4KVRG-E1
HAORI
|
TOSHIBA | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RAV-GM802ATW-E/RAV-HM801UTP-E
DI
|
TOSHIBA | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.87 | -15° | 6.70 | 5.10 | |
|
RAV-GP1401AT-E1/RAV-HM1401BTP-E
SDI
|
TOSHIBA | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.28 | 3.86 | -27° | 12.50 | 9.60 | |
|
RAV-GP801ATW-E/RAV-HM801FT-E
SDI
|
TOSHIBA | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.43 | 4.43 | 3.38 | -27° | 7.10 | 5.10 | |
|
RAS-13P2AVSG-E/RAS-B13P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RAS-13P2AVSG-E/RAS-B13P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RAV-GP561ATW-E/RAV-HM561MUTP-E
SDI
|
TOSHIBA | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.27 | 4.32 | 3.50 | -27° | 5.00 | 3.80 | |
|
PUZ-ZM140VDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
RAV-GM802ATW-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.48 | 3.87 | -15° | 6.90 | 5.10 | |
|
RAS-2M60S4AVG-ND/RAS-B25G3KVSG-ND+RAS-B50G3KVSG-ND
Multi
|
TOSHIBA | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 3.74 | -25° | 6.00 | 6.50 | |
|
PUZ-ZM125VDA/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
MUZ-FT35VGHZ/MSZ-FT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
MUZ-FT35VGHZ2/MSZ-FT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
PUZ-ZM125YDA/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
RAV-GM902ATW-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.60 | 4.00 | -15° | 8.00 | 6.30 | |
|
PUZ-M100YKA2/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
RAV-GM902ATW-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.75 | 4.30 | 4.00 | -15° | 8.00 | 6.30 | |
|
PUZ-ZM140VDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 |