Filters · 2 active
Manufacturer:
Mitsubishi Heavy Industries
AIRCLASS
(0)
AIRWELL
(11)
ATLANTIC
(12)
AUX
(4)
BOSCH
(17)
BRYANT
(5)
Buderus
(8)
CARRIER
(37)
CIAT
(11)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(5)
DAIKIN
(81)
EQUATION
(1)
FUJI ELECTRIC
(18)
FUJITSU
(56)
Fujitsu Atlantic
(29)
GENERAL
(26)
GREE
(7)
GSS
(0)
HAIER
(234)
HEC
(2)
HEIWA
(1)
HISENSE
(44)
HITACHI
(37)
IVT
(1)
Inventor
(46)
KAYSUN
(19)
LG
(104)
MIDEA
(255)
MITSUBISHI ELECTRIC
(171)
NORD
(28)
Nobu
(7)
PANASONIC
(33)
RIELLO
(14)
Rotenso
(4)
SAMSUNG
(77)
THERMOR
(12)
TOSHIBA
(96)
Viessmann
(5)
Vulcano
(6)
WESTPOINT
(0)
YORK
(12)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.80 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.94 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.60 | 2.90 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
FDC125VNX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.94 | 4.67 | 3.00 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.79 | 3.00 | 12.50 | 14.00 | ||
|
FDC140VNA-W/FDF71VH/FDF71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF71VH/FDF71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDF71VH1/FDF71VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF71VH1/FDF71VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
FDC125VSX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.94 | 4.36 | 2.91 | 12.50 | 14.00 | ||
|
FDC125VNX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.44 | 3.03 | 12.50 | 11.40 | ||
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
FDC125VSX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.26 | 2.79 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.14 | 2.56 | 14.00 | 15.50 | ||
|
FDC125VNX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.20 | 2.90 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 2.70 | 12.50 | 11.40 | ||
|
FDC140VNX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.35 | 2.91 | 14.00 | 13.00 | ||
|
FDC200VSA/SRK100ZR-W/SRK100ZR-W
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.67 | 3.02 | 19.00 | 12.50 | ||
|
SRC71ZTL-W/SRK71ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.38 | -10° | 7.10 | 6.20 | |
|
FDC125VNX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.06 | 2.90 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.06 | 2.90 | 12.50 | 11.40 | ||
|
FDC125VNA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
FDC250VSA-W/FDF125VH/FDF125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDF125VH1/FDF125VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC140VNX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.17 | 2.90 | 14.00 | 13.00 | ||
|
FDC250VSA/FDF125VD/FDF125VD
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.45 | 4.25 | 3.18 | 24.00 | 14.20 | ||
|
FDC125VSX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.02 | 2.60 | 12.50 | 14.00 | ||
|
SRC60ZSX-W3/FDTC60VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.45 | 4.10 | 3.13 | -20° | 5.60 | 5.10 | |
|
FDC140VNA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.10 | 4.17 | 3.11 | 13.00 | 10.50 | ||
|
FDC140VSA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.03 | 4.17 | 3.11 | 13.60 | 10.50 | ||
|
FDC140VNX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
FDC140VSX/FDE71VH/FDE71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.06 | 3.49 | 14.00 | 13.00 | ||
|
FDC140VSA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC140VNA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
FDC125VSX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 2.70 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 3.96 | 2.50 | 14.00 | 15.50 | ||
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
FDC140VNX-W/FDUM140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 3.99 | 2.90 | 14.00 | 13.00 | ||
|
FDC140VNX-W/FDU140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 3.99 | 2.90 | 14.00 | 13.00 | ||
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC200VSA-W/SRK100ZR-W/SRK100ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.36 | 3.26 | 20.00 | 12.50 | ||
|
FDC125VNA/FDF125VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.96 | 3.38 | 12.50 | 9.80 |