Filters · 2 active
Manufacturer:
Mitsubishi Heavy Industries
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(5)
AUX
(1)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(4)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(183)
EQUATION
(0)
FUJI ELECTRIC
(43)
FUJITSU
(123)
Fujitsu Atlantic
(61)
GENERAL
(55)
GREE
(0)
GSS
(0)
HAIER
(135)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(27)
IVT
(0)
Inventor
(11)
KAYSUN
(6)
LG
(58)
MIDEA
(49)
MITSUBISHI ELECTRIC
(167)
NORD
(0)
Nobu
(0)
PANASONIC
(23)
RIELLO
(1)
Rotenso
(5)
SAMSUNG
(27)
THERMOR
(4)
TOSHIBA
(76)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC90VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
FDC100VNA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC250VSA-W/FDF125VH/FDF125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDF125VH1/FDF125VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC100VNX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.18 | 4.18 | -20° | 10.00 | 11.20 | |
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC71VNP-W/FDE71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.74 | 4.32 | 3.62 | -15° | 7.10 | 5.70 | |
|
FDC100VSX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.84 | 4.17 | 4.18 | -20° | 10.00 | 11.20 | |
|
FDC250VSA/FDF125VD/FDF125VD
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.45 | 4.25 | 3.18 | 24.00 | 14.20 | ||
|
FDC100VNX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VNX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VNX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDT100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.32 | 4.34 | -20° | 10.00 | 11.20 | |
|
FDC100VSX/FDU100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC100VSX/FDUM100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.19 | 4.10 | 3.71 | -20° | 10.00 | 10.90 | |
|
FDC125VNA-W/FDU125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VNA-W/FDUM125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDU125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDUM125VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.57 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC71VNP-W/FDT71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.65 | 4.38 | 4.10 | -15° | 7.10 | 5.70 | |
|
FDC140VNA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.10 | 4.17 | 3.11 | 13.00 | 10.50 | ||
|
FDC100VNA-W/FDUM50VH/FDUM50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.00 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDUM50VH/FDUM50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.00 | 3.68 | -20° | 10.00 | 8.50 | |
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
FDC125VNA/FDU125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA/FDU125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC140VSA/FDF140VD
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.03 | 4.17 | 3.11 | 13.60 | 10.50 | ||
|
FDC125VNA/FDUM125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.26 | 4.13 | 3.79 | 12.50 | 9.80 | ||
|
FDC71VNP-W/FDU71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.12 | 3.76 | -15° | 7.10 | 5.70 | |
|
FDC71VNP-W/FDUM71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.22 | 4.12 | 3.76 | -15° | 7.10 | 5.70 | |
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC100VNA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE50VH/FDE50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.71 | 4.10 | 3.75 | -20° | 10.00 | 8.50 | |
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
FDC140VNA-W/FDU140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.30 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDUM140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.30 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDUM140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.30 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDU140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.29 | 4.01 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VNX-W/FDUM140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 3.99 | 2.90 | 14.00 | 13.00 |