Filters · 2 active
Manufacturer:
Mitsubishi Heavy Industries
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(14)
BRYANT
(0)
Buderus
(4)
CARRIER
(21)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(56)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(20)
Fujitsu Atlantic
(8)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(76)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(0)
MIDEA
(33)
MITSUBISHI ELECTRIC
(244)
NORD
(0)
Nobu
(0)
PANASONIC
(143)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(92)
THERMOR
(0)
TOSHIBA
(124)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
SRC60ZSX-W3/FDT60VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.74 | 5.00 | 4.29 | -20° | 5.60 | 5.20 | |
|
SRC25ZSX-W/SRK25ZSX-W
ZSX-W
|
Mitsubishi Heavy Industries | Wall mounted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.30 | 5.20 | 5.42 | -20° | 2.50 | 3.00 | |
|
SRC40ZSX-W1/FDT40VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.63 | 4.62 | 4.37 | -20° | 4.00 | 3.90 | |
|
FDC71VNX-W/FDT40VH/FDT40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.66 | 4.38 | -20° | 7.10 | 5.80 | |
|
SRC50ZSX-W3/FDT50VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.93 | 4.63 | 4.12 | -20° | 5.00 | 4.00 | |
|
FDC71VNX-W/FDT71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.61 | 4.58 | -20° | 7.10 | 5.80 | |
|
FDC71VNX-W/FDU71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.47 | 4.49 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDUM71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.89 | 4.45 | 4.49 | -20° | 7.10 | 6.00 | |
|
FDC100VNX-W/FDT100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.44 | 4.52 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDT100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.44 | 4.52 | -20° | 10.00 | 11.20 | |
|
FDC100VNA-W/FDT100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.08 | 4.60 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDT100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.08 | 4.60 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/SRK50ZSX-W/SRK50ZSX-W
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.05 | 4.47 | 4.29 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/SRK50ZSX-W/SRK50ZSX-W
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.05 | 4.47 | 4.29 | -20° | 10.00 | 8.50 | |
|
SRC60ZSX-W3/FDE60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.72 | 4.41 | 3.60 | -20° | 5.60 | 4.50 | |
|
SRC60ZSX-W3/FDUM60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.43 | 4.37 | 3.83 | -20° | 5.60 | 4.70 | |
|
FDC100VNX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDE100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.24 | 4.45 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/SRK50ZSX-W/SRK50ZSX-W
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.66 | 4.25 | 4.31 | -20° | 10.00 | 11.20 | |
|
FDC100VNA-W/FDT50VH/FDT50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.41 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDT50VH/FDT50VH
VNA-W/VSA-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.41 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VNX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.26 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
SRC40ZSX-W1/FDTC40VH
ZSX-W
|
Mitsubishi Heavy Industries | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.37 | 3.98 | -20° | 4.00 | 4.00 | |
|
FDC71VNX-W/FDE71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.58 | 4.45 | 4.28 | -20° | 7.10 | 6.00 | |
|
FDC100VNA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC71VNX-W/FDE40VH/FDE40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.48 | 4.49 | 3.81 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDTC40VH/FDTC40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.37 | -20° | 7.10 | 6.00 | |
|
FDC100VNX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC71VNX-W/FDUM40VH/FDUM40VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.38 | 4.15 | 4.44 | -20° | 7.10 | 6.00 | |
|
FDC100VNA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDUM100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDU100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.19 | 4.21 | -20° | 10.00 | 8.50 |