Filters · 3 active
Manufacturer:
AUX
NORD
YORK
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ND35MDAHRA/1N35MEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 3.50 | 3.60 | |
|
NF25DBAHRA/1N25MEAFRA
NORD - Console
|
NORD | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.60 | -10° | 2.60 | 2.40 | |
|
NF35DBAHRA/1N35MEAFRA
NORD - Console
|
NORD | Console | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
RXYM52M(2)-T1A+FTXM26CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.70 | 4.30 | -10° | 5.20 | 4.70 | |
|
RXYM52M(2)-T1A+FTXM26CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.70 | 4.30 | -10° | 5.20 | 4.70 | |
|
ND50MDAHRA/1N50KEAFRA
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
ND50MDAHRA/1N50KEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 4.00 | -10° | 5.00 | 4.50 | |
|
AS50SAT1-W/US50SAT1
NORD - S
|
NORD | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 4.00 | -10° | 5.30 | 4.70 | |
|
AS71QUA1-H/1U71QUA1
NORD - P Premium
|
NORD | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
ND71MFAHRA/1N71WEAFRA
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
ND71MFAHRA/1N71WEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AM2-H18/4DR3HA+AMWM-H09/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.30 | -10° | 5.20 | 4.70 | |
|
AM2-H18/4DR3HA+AMWM-H09/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.30 | -10° | 5.20 | 4.70 | |
|
AS50QUA1-H/1U50QUA1
NORD - P Premium
|
NORD | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.30 | 4.60 | |
|
2N50MEAFRA/AS35SAT1-W/AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.00 | 4.20 | |
|
2N50MEAFRA-W/AS35SAT1-W/AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 5.00 | 4.20 | |
|
YHKF09XEEDMH-RY / YHKF09YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.60 | -10° | 2.60 | 2.40 | |
|
AM4-H36/4DR3B+AMWM-H18/4R3HA(M*)x2
M SERIES
|
AUX | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.71 | -10° | 10.55 | 8.80 | |
|
AM4-H36/4DR3B+AMWM-H18/4R3HA(C*)x2
C SERIES
|
AUX | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.71 | -10° | 10.55 | 8.80 | |
|
RXYM105M(4)-T1B+FTXM52CU1-Ax2
CU PRO SERIES
|
AUX | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.71 | -10° | 10.55 | 8.80 | |
|
RXYM105M(4)-T1B+FTXM52CA-Ax2
CA PRO SERIES
|
AUX | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.71 | -10° | 10.55 | 8.80 | |
|
NB71CEAHRA/1N71WEAFRA-W
NORD - Cassette
|
NORD | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 7.10 | 5.50 | |
|
NB71CEAHRA/1N71WEAFRA
NORD - Cassette
|
NORD | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 7.10 | 5.50 | |
|
AS25SAT1-W/US25SAT1
NORD - S
|
NORD | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
2N40MEAFRA/AS25SAT1-W/AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2N40MEAFRA/AS25SAT1-W/AS25SAT1-W
NORD - Multi
|
NORD | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2N40MEAFRA-W/AS25SAT1-W/AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
2N40MEAFRA-W/AS25SAT1-W/AS25SAT1-W
NORD - Multi
|
NORD | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.50 | |
|
ND105MFAHRA/1N105XEAFRA
NORD - MSP Duct
|
NORD | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.20 | -10° | 9.50 | 7.80 | |
|
ND105MFAHRA/1N105XEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.20 | -10° | 9.50 | 7.80 | |
|
AS35SAT1-W/US35SAT1
NORD - S
|
NORD | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
YUKF55BYOEBMO-1/YFKF55BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -15° | 15.50 | 11.90 | |
|
ND125MGAHRA/1N125TEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 2.95 | 12.50 | 9.60 | ||
|
ND35LBAHRA/1N35MEAFRA
NORD - LSP Duct
|
NORD | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.71 | -10° | 3.50 | 2.60 | |
|
AS25QUA1-H/1U25QUA1
NORD - P Premium
|
NORD | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 2.70 | 2.40 | |
|
YUKF36BYEEBMO-1/YFKF36BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AS35QUA1-H/1U35QUA1
NORD - P Premium
|
NORD | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.10 | -10° | 3.30 | 2.80 | |
|
YUKF30BYEEBMO-1/YEKF30BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
YUKF55BYOEBMO-1/YEKF55BXOEBM-R1
Grande Duct R32
|
YORK | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -15° | 15.30 | 12.50 | |
|
NF50DBAHRA/1N50KEAFRA
NORD - Console
|
NORD | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.10 | 3.71 | -10° | 5.00 | 4.20 | |
|
YHKF12XEEDMH-RY / YHKF12YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
AL-H30/4DR3HB3(U) / AUMD-H30/4DR3HC2
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
RXYL90M-T1B/FDMD90M-B
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
YUKF18BYEEBMO-1/YEKF18BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
YUKF36BYEEBMO-1/YEKF36BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
YUKF42BYEEBMO-1/YEKF42BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -15° | 12.10 | 9.50 | |
|
YUKF30BYEEBMO-1/YKKF30BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
YUKF12BYEEBMO-1/YEKF12BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
YUKF36BYOEBMO-1/YEKF36BXOEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
AL-H36/4DR3C3(U) / AUMD-H36/4DR3HC2
M-Ducted
|
AUX | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.01 | -10° | 10.55 | 8.40 |