Filters · 3 active
Manufacturer:
BOSCH
Nobu
AIRCLASS
(3)
AIRWELL
(70)
ATLANTIC
(26)
AUX
(70)
BRYANT
(4)
Buderus
(27)
CARRIER
(122)
CIAT
(41)
COLIBRI
(4)
CONFORT AIR
(3)
Candy
(7)
DAIKIN
(754)
EQUATION
(4)
FUJI ELECTRIC
(118)
FUJITSU
(316)
Fujitsu Atlantic
(150)
GENERAL
(164)
GREE
(81)
GSS
(3)
HAIER
(489)
HEC
(3)
HEIWA
(5)
HISENSE
(221)
HITACHI
(154)
IVT
(6)
Inventor
(123)
KAYSUN
(64)
LG
(287)
MIDEA
(673)
MITSUBISHI ELECTRIC
(564)
Mitsubishi Heavy Industries
(388)
NORD
(45)
PANASONIC
(253)
RIELLO
(43)
Rotenso
(8)
SAMSUNG
(165)
THERMOR
(41)
TOSHIBA
(263)
Viessmann
(21)
Vulcano
(14)
WESTPOINT
(15)
YORK
(35)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
CL5100i CNO 35 HE / CL5100i CN 35 HE
Climate 5100i
|
BOSCH | Console | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.02 | -10° | 3.60 | 3.60 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HES
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HER
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 E
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
CL7000M 79/3 E / CL7000iU W 53 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL7000i 53 E / CL7000iU W 53 E
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 ES
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 EB
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
CL7100i 50 HE / CL7100i W 50 HE
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HES
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HEB
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CL7000M 53/2 E /CL5000iU W 26 E +CL5000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL7000M 53/2 E /CL4000iU W 26 E +CL4000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.20 | -10° | 5.30 | 4.50 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
CL7000i 41 E / CL7000iU W 41 E
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 ES
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 EB
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
CL5001L 70 E / CL5000iL CF 70 E
Climate 5001 L
|
BOSCH | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL6001i 70 E / CL6001iU W 70 E
Climate 6000i
|
BOSCH | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL6001i 35 E / CL6001iU W 35 E
Climate 6000i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CL6102i 35 HE / CL6102i W 35 HE
Climate 6102i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CL5100i 35 HE/CL5100i W 35 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 |