Filters · 3 active
Manufacturer:
BOSCH
PANASONIC
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BRYANT
(0)
Buderus
(4)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(4)
Candy
(0)
DAIKIN
(11)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(12)
Fujitsu Atlantic
(0)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(14)
IVT
(0)
Inventor
(14)
KAYSUN
(0)
LG
(0)
MIDEA
(33)
MITSUBISHI ELECTRIC
(38)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(37)
THERMOR
(0)
TOSHIBA
(43)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(5)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-HZ35ZKE / CS-HZ35ZKE
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.30 | 5.00 | -25° | 3.50 | 4.00 | |
|
CU-HZ35ZKE / CS-HZ35ZKE-H
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.30 | 5.00 | -25° | 3.50 | 4.00 | |
|
CU-HZ25ZKE / CS-HZ25ZKE
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.30 | 5.61 | -25° | 2.50 | 3.20 | |
|
CU-HZ25ZKE / CS-HZ25ZKE-H
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.30 | 5.61 | -25° | 2.50 | 3.20 | |
|
CU-HZ25ZKE-5 / CS-HZ25ZKE-5
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.30 | 5.61 | -25° | 2.50 | 3.20 | |
|
CU-HZ25ZKE-5 / CS-HZ25ZKE-5-H
2023
|
PANASONIC | Wall mounted | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.30 | 5.61 | -25° | 2.50 | 3.20 | |
|
CU-HZ25XKE / CS-HZ25XKE
2022
|
PANASONIC | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.30 | 5.61 | -25° | 2.50 | 3.00 | |
|
CU-HZ25XKE-5 / CS-HZ25XKE-5
2022
|
PANASONIC | Wall mounted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.30 | 5.61 | -25° | 2.50 | 3.00 | |
|
CU-Z25UFEA-1 / CS-Z25UFEAW-1
2018
|
PANASONIC | Console | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.70 | 4.59 | -25° | 2.50 | 3.00 | |
|
CU-Z25CFEA-1 / CS-Z25CFEAW-1
2025
|
PANASONIC | Console | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.70 | 4.59 | -25° | 2.50 | 3.00 | |
|
CU-HZ35XKE / CS-HZ35XKE
2022
|
PANASONIC | Wall mounted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.30 | 5.00 | -25° | 3.50 | 4.00 | |
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 | |
|
CU-NZ50YKE / CS-NZ50YKE
2023
|
PANASONIC | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.26 | -25° | 5.00 | 4.40 | |
|
CU-NZ50YKE / CS-NZ50YKE-1
2024
|
PANASONIC | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.26 | -25° | 5.00 | 4.40 | |
|
CU-Z35UFEA-1 / CS-Z35UFEAW-1
2018
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
CU-Z35CFEA-1 / CS-Z35CFEAW-1
2025
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
CU-2Z50ABEC/CS-HZ25ZKE/CS-HZ25ZKE
2024
|
PANASONIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.60 | 4.71 | -25° | 5.30 | 5.20 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HES
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HER
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CU-NZ35YKE / CS-NZ35YKE
2023
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
CU-NZ35YKE / CS-NZ35YKE-1
2024
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
CU-3Z75ABEC/CS-HZ35ZKE/CS-HZ35ZKE
2024
|
PANASONIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.34 | -25° | 7.00 | 5.70 | |
|
CU-2Z50ABEC/CS-Z25CKEW/CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.40 | 4.18 | -25° | 5.30 | 5.10 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-3Z75ABEC/CS-Z50CKEW/CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.32 | -25° | 7.50 | 5.60 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 |