Filters · 2 active
Manufacturer:
Buderus
PANASONIC
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-60PZH3E5 / S-60PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.40 | -20° | 6.00 | 4.60 | |
|
CU-Z35CBEA / CS-Z35CD3EAW
2025
|
PANASONIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.82 | -15° | 3.50 | 2.80 | |
|
AC176iP-2,6 / AC176iP-2,6 W
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W S
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
U-200PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 3.94 | 3.80 | -20° | 19.00 | 15.70 | |
|
U-71PZH4E5/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E8/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
AC186i.3-4,1 / AC186i.3-4,1 W
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
AC186i.3-4,1 / AC186i.3-4,1 WB
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CU-Z25UBEA / CS-Z25UD3EAW
2017
|
PANASONIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
AC176i.3-2,6 / AC176i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
AC176i.3-5,3 / AC176i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
U-50PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.00 | 3.62 | -15° | 5.00 | 3.80 | |
|
AC176i.3-7,0 / AC176i.3-7,0 W
Logacool
|
Buderus | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
U-50PZ3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
U-100PZH4E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 | |
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 | |
|
CU-Z50CBEA / CS-Z50CD3EAW
2025
|
PANASONIC | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
U-50PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.73 | -15° | 5.00 | 4.00 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
AC176i.3-3,5 / AC176i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
U-50PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
U-60PZ3E5A / S-60PY3E
2022
|
PANASONIC | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.61 | -15° | 6.00 | 4.60 | |
|
AC176iP-3,5 / AC176iP-3,5 W
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W S
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CU-2TZ50CBE/CS-TZ25CKEW/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 3.97 | -15° | 5.00 | 4.20 | |
|
CU-Z50UBEA / CS-Z50UFEAW
2018
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-Z50CBEA / CS-Z50CFEAW
2025
|
PANASONIC | Console | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.74 | -15° | 5.00 | 4.40 | |
|
CU-TZ25CKE / CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.60 | 4.18 | -15° | 2.50 | 2.40 | |
|
U-200PZH4E8 / S-6071PF3E(3x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PF3E(4x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
CU-TZ25ZKE / CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.60 | 4.18 | -15° | 2.50 | 2.40 | |
|
CU-3Z68CBE / CS-Z50CKEW / CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.15 | -15° | 6.80 | 5.20 | |
|
CU-4Z68CBE / CS-Z50CKEW / CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.15 | -15° | 6.80 | 5.20 | |
|
CU-TZ35CKE / CS-TZ35CKEW
2025
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.60 | 4.04 | -15° | 3.50 | 2.80 | |
|
CU-TZ20ZKE / CS-TZ20ZKEW
2023
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.15 | -15° | 2.00 | 2.10 | |
|
CU-TZ20CKE / CS-TZ20CKEW
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.15 | -15° | 2.00 | 2.10 | |
|
U-250PZH4E8 + P‐VTVF250MC5‐PE
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
CU-Z35UBEA / CS-Z35UB4EAW
2017
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.31 | -15° | 3.50 | 3.00 | |
|
U-125PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
U-125PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
CU-TZ25WKE / CS-TZ25WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.18 | -15° | 2.50 | 2.40 |