Filters · 3 active
Manufacturer:
PANASONIC
RIELLO
AIRCLASS
(0)
AIRWELL
(61)
ATLANTIC
(18)
AUX
(62)
BOSCH
(56)
BRYANT
(6)
Buderus
(16)
CARRIER
(98)
CIAT
(36)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(12)
DAIKIN
(468)
EQUATION
(2)
FUJI ELECTRIC
(102)
FUJITSU
(261)
Fujitsu Atlantic
(129)
GENERAL
(134)
GREE
(58)
GSS
(4)
HAIER
(403)
HEC
(3)
HEIWA
(3)
HISENSE
(199)
HITACHI
(97)
IVT
(0)
Inventor
(109)
KAYSUN
(60)
LG
(230)
MIDEA
(611)
MITSUBISHI ELECTRIC
(310)
Mitsubishi Heavy Industries
(221)
NORD
(39)
Nobu
(8)
Rotenso
(8)
SAMSUNG
(107)
THERMOR
(35)
TOSHIBA
(175)
Viessmann
(22)
Vulcano
(15)
WESTPOINT
(3)
YORK
(35)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-125PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.04 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
U-125PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
U-71PZ3E5A / S-6071PU3E
2021
|
PANASONIC | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 4.23 | -15° | 7.10 | 5.20 | |
|
U-140PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.97 | 4.14 | 3.33 | -20° | 13.40 | 9.50 | |
|
U-140PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.97 | 4.14 | 3.33 | -20° | 13.40 | 9.50 | |
|
U-250PZH4E8 / S-6071PF3E(4x)
2024
|
PANASONIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.00 | 3.75 | -20° | 21.50 | 17.20 | |
|
U-140PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
U-140PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.64 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
U-71PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-125PZH4E5 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-71PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.70 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-50PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.61 | -20° | 5.00 | 4.00 | |
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
U-140PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E5 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-60PZH3E5 / S-60PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.40 | -20° | 6.00 | 4.60 | |
|
U-200PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 3.94 | 3.80 | -20° | 19.00 | 15.70 | |
|
SC210HIDS8/AIC210HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
DC280HIDS8/AIC280HIDS8
Ducted
|
RIELLO | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
U-50PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.00 | 3.62 | -15° | 5.00 | 3.80 | |
|
U-100PZH4E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 | |
|
CU-Z50CBEA / CS-Z50CD3EAW
2025
|
PANASONIC | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
U-50PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.73 | -15° | 5.00 | 4.00 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
CC250HIDS8*/AIC250HIDS8*
Console
|
RIELLO | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
U-50PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
U-60PZ3E5A / S-60PY3E
2022
|
PANASONIC | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.61 | -15° | 6.00 | 4.60 | |
|
U-200PZH4E8 / S-6071PF3E(3x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PF3E(4x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
DC250HIDS8/AIC250HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
KC280HIDS8/AIC280HIDS8
Cassette
|
RIELLO | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
DC210HIDS8/AIC210HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-250PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.48 | 3.90 | 3.80 | -20° | 22.00 | 16.70 | |
|
DC217HIDS8/AIC217HIDT8
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
DC212HIDS8*/AIC212HIDS8*
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
KC235HIDS8/AIC235HIDS8
Cassette
|
RIELLO | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
CU-TZ50WKE / CS-TZ50WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50ZKE / CS-TZ50ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50CKE / CS-TZ50CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UD3EAW
2017
|
PANASONIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.35 | -15° | 5.10 | 4.00 |