Filters · 2 active
Manufacturer:
PANASONIC
AIRCLASS
(2)
AIRWELL
(65)
ATLANTIC
(27)
AUX
(66)
BOSCH
(65)
BRYANT
(6)
Buderus
(20)
CARRIER
(101)
CIAT
(42)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(563)
EQUATION
(5)
FUJI ELECTRIC
(150)
FUJITSU
(353)
Fujitsu Atlantic
(180)
GENERAL
(188)
GREE
(95)
GSS
(4)
HAIER
(451)
HEC
(5)
HEIWA
(5)
HISENSE
(213)
HITACHI
(116)
IVT
(1)
Inventor
(114)
KAYSUN
(66)
LG
(316)
MIDEA
(644)
MITSUBISHI ELECTRIC
(497)
Mitsubishi Heavy Industries
(284)
NORD
(40)
Nobu
(8)
RIELLO
(45)
Rotenso
(8)
SAMSUNG
(147)
THERMOR
(43)
TOSHIBA
(193)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(9)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-36PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | 4.17 | -20° | 3.60 | 3.60 | |
|
U-60PZH3E5 / S-6071PF3E
2021
|
PANASONIC | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.74 | -20° | 5.70 | 4.70 | |
|
U-100PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.30 | 3.88 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-125PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.12 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
U-125PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
U-60PZ3E5A / S-6071PF3E
2021
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 4.04 | -15° | 5.70 | 4.40 | |
|
U-125PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.04 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
U-125PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
U-50PZ3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.94 | -15° | 4.70 | 4.00 | |
|
U-140PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.97 | 4.14 | 3.33 | -20° | 13.40 | 9.50 | |
|
U-140PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.97 | 4.14 | 3.33 | -20° | 13.40 | 9.50 | |
|
U-250PZH4E8 / S-6071PF3E(4x)
2024
|
PANASONIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.00 | 3.75 | -20° | 21.50 | 17.20 | |
|
U-140PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
U-140PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.64 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
CU-2Z50ABEC/CS-Z25CKEW/CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.40 | 4.18 | -25° | 5.30 | 5.10 | |
|
CU-Z25CBEA / CS-Z25CD3EAW
2025
|
PANASONIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
U-250PZH4E8 + P‐VTVF250NC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-250PZH4E8 + P‐VTVF250PC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-36PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.61 | -15° | 3.50 | 2.80 | |
|
U-125PZH4E5 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-2545PK4E(4x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-100PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
U-50PZH3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.61 | -20° | 5.00 | 4.00 | |
|
U-100PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.93 | -15° | 10.00 | 10.00 | |
|
CU-3Z75ABEC/CS-Z50CKEW/CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.32 | -25° | 7.50 | 5.60 | |
|
U-100PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 4.24 | -15° | 10.00 | 10.00 | |
|
CU-Z42YKEA / CS-Z42YKEA
2022
|
PANASONIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
CU-Z42YKEA-1 / CS-Z42YKEA-1
2024
|
PANASONIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
U-100PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 4.24 | -15° | 10.00 | 10.00 | |
|
U-140PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E5 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-36PZ3E5 / S-36PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.29 | -15° | 3.60 | 2.80 | |
|
U-60PZH3E5 / S-60PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.40 | -20° | 6.00 | 4.60 | |
|
CU-Z35CBEA / CS-Z35CD3EAW
2025
|
PANASONIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.82 | -15° | 3.50 | 2.80 | |
|
U-200PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 3.94 | 3.80 | -20° | 19.00 | 15.70 | |
|
CU-Z25UBEA / CS-Z25UD3EAW
2017
|
PANASONIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
U-50PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.00 | 3.62 | -15° | 5.00 | 3.80 | |
|
U-50PZ3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.20 | -15° | 5.00 | 4.00 | |
|
U-100PZH4E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 |