Filters · 3 active
Manufacturer:
Buderus
COLIBRI
Rotenso
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
CARRIER
(149)
CIAT
(44)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC186i.3-2,6 / AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-2,6 / AC186i.3-2,6 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-2,0 / AC186i.3-2,0 W
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC186i.3-2,0 / AC186i.3-2,0 WB
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC-7,9 MS E+ / AC186i.3-5,3 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
AC186i.3-5.3 / AC186i.3-5.3 W
Logacool
|
Buderus | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC186i.3-5,3 / AC186i.3-5,3 WB
Logacool
|
Buderus | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC-5,3 MS E+ / AC186i.3-2,6 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
COLI09D8SHF/COLI09D8SHC
Wall mounted
|
COLIBRI | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
AC176iP-2,6 / AC176iP-2,6 W
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W S
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC186i.3-4,1 / AC186i.3-4,1 W
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
AC186i.3-4,1 / AC186i.3-4,1 WB
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
AC176i.3-2,6 / AC176i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
AC176i.3-5,3 / AC176i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AC176i.3-7,0 / AC176i.3-7,0 W
Logacool
|
Buderus | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AC176i.3-3,5 / AC176i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
COLI12D8SHF/COLI12D8SHC
Wall mounted
|
COLIBRI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
AC176iP-3,5 / AC176iP-3,5 W
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W S
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
N160Xi R15/UO160Xo R15
Nevo
|
Rotenso | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
N120Xi R15/UO120Xo R14
Nevo
|
Rotenso | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
N140Xi R15/UO140Xo R15
Nevo
|
Rotenso | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
J140Xi R14/UO140Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
J160Xi R14/UO160Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
AC166i.2-5,3 / AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
COLI18R8SHF/COLI18R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
AC166i.2-3,5 / AC166i.2-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC166i.2-3,5 / AC166i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC-5,3 MS / AC166i-2,6 MS CN + AC166i-2,6 MS CN
Logacool
|
Buderus | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
AC166i.2-7,0 / AC166i.2-7,0 W
Logacool
|
Buderus | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
AC166i.2-7,0 / AC166i.3-7,0 W
Logacool
|
Buderus | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
AC166i.2-2,6 / AC166i.2-2,6 W
Logacool
|
Buderus | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
AC166i.2-2,6 / AC166i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
T120Xi R16/UO120Xo R14
Tenji
|
Rotenso | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
T160Xi R16/UO160Xo R15
Tenji
|
Rotenso | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
T140Xi R16/UO140Xo R15
Tenji
|
Rotenso | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
AC-4,1 MS / AC166i.2-2,6 W + AC166i.2-2,6 W
Logacool
|
Buderus | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
AC-10,6 MS / AC166i.2-5,3 W+ AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
AC-4,1 MS / AC166i-2,1 MS D + AC166i-2,1 MS D
Logacool
|
Buderus | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
AC-5,3 MS / AC166i-2,6 MS D + AC166i-2,6 MS D
Logacool
|
Buderus | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
AC-5,3 MS / AC176i.3-2,6 W + AC176i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
AC-6,2 MS / AC166i.2-2,6 W + AC166i.2-3,5 W
Logacool
|
Buderus | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
AC-7,9 MS / AC166i.2-2,6 W + AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
AC-5,3 MS / AC166i.2-2,6 W + AC166i.2-2,6 W
Logacool
|
Buderus | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
COLI09R8SHF/COLI09R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 |