Filters · 3 active
Manufacturer:
Rotenso
SAMSUNG
AIRCLASS
(1)
AIRWELL
(74)
ATLANTIC
(35)
AUX
(66)
BOSCH
(84)
BRYANT
(6)
Buderus
(28)
CARRIER
(124)
CIAT
(42)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(17)
DAIKIN
(677)
EQUATION
(5)
FUJI ELECTRIC
(145)
FUJITSU
(355)
Fujitsu Atlantic
(178)
GENERAL
(201)
GREE
(106)
GSS
(4)
HAIER
(533)
HEC
(5)
HEIWA
(6)
HISENSE
(273)
HITACHI
(139)
IVT
(4)
Inventor
(136)
KAYSUN
(67)
LG
(314)
MIDEA
(747)
MITSUBISHI ELECTRIC
(511)
Mitsubishi Heavy Industries
(354)
NORD
(50)
Nobu
(8)
PANASONIC
(221)
RIELLO
(45)
THERMOR
(58)
TOSHIBA
(238)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(15)
YORK
(38)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC120BXAPNG / AC120BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 4.00 | -25° | 12.10 | 9.50 | |
|
AC140BXAPNG / AC140BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.63 | -25° | 13.40 | 9.50 | |
|
AC071BXAPKG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC071BXAPNG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC052RXADKG/AC052RN4DKG
CAC
|
SAMSUNG | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.30 | 4.03 | -20° | 5.00 | 2.60 | |
|
AC035BXAPKG/AC035BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | 3.81 | -25° | 3.50 | 2.30 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
AC120BXAPNG / AC120BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.77 | -25° | 12.10 | 9.20 | |
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
AR70F12C1AWN/AR70F12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
AR70F12C1ABN/AR70F12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
AR70H12C1ABN/AR70H12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
AR70H12C1AWN/AR70H12C1AWX
RAC
|
SAMSUNG | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.80 | 3.74 | -11° | 3.50 | 2.40 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
AR12TXCACWKN/AR12TXCACWKX
RAC
|
SAMSUNG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
AR12BXFYDWKN/AR12BXFYDWKX
RAC
|
SAMSUNG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
AC100RXADKG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.61 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.69 | -20° | 10.00 | 5.30 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
AC052BXAPKG/AC052BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -25° | 5.00 | 3.90 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.55 | -20° | 10.00 | 5.30 | |
|
AJ120HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.45 | 3.61 | -10° | 12.00 | 8.37 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
AJ100HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.26 | 4.28 | 3.87 | -10° | 9.80 | 7.91 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
AR60F09C1AWN/AR60F09C1AWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
AR60F09CAAWN/AR60F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
AR70H12CACWN/AR70H12CACWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.60 | 3.92 | -11° | 3.50 | 2.30 | |
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AR80F12CAAWN/AR80F12CAAWX
RAC
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.60 | 3.39 | -11° | 3.50 | 2.40 | |
|
AR80H12CAAWN/AR80H12CAAWX
RAC
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.60 | 3.39 | -11° | 3.50 | 2.40 | |
|
AR60F12C1AWN/AR60F12C1AWX
RAC
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.60 | 3.92 | -11° | 3.50 | 2.30 | |
|
AR60F12CAAWN/AR60F12CAAWX
RAC
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.60 | 3.92 | -11° | 3.50 | 2.30 | |
|
AR50F12C1CHN/AR50F12C1CHX
RAC
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 3.54 | -11° | 3.50 | 2.40 | |
|
AR12TXFYBWKN/AR12TXFYBWKX
RAC
|
SAMSUNG | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.60 | 4.26 | -11° | 3.50 | 2.40 | |
|
AR70H15C1AWN/AR70H15C1AWX
RAC
|
SAMSUNG | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.60 | 3.73 | -11° | 4.30 | 2.70 | |
|
AR70F15C1AWN/AR70F15C1AWX
RAC
|
SAMSUNG | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.73 | -11° | 4.30 | 2.70 | |
|
N160Xi R15/UO160Xo R15
Nevo
|
Rotenso | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 |