Filters · 4 active
Manufacturer:
Buderus
GSS
Rotenso
WESTPOINT
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC186i.3-2,6 / AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-2,6 / AC186i.3-2,6 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-3,5 / AC186i.3-3,5 WB
Logacool
|
Buderus | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.70 | -10° | 3.40 | 2.20 | |
|
AC186i.3-2,0 / AC186i.3-2,0 W
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC186i.3-2,0 / AC186i.3-2,0 WB
Logacool
|
Buderus | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC-7,9 MS E+ / AC186i.3-5,3 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
WIMO-09326.MH / WIM-09326.MH
WIM 326
|
WESTPOINT | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
WIMO-24325.MH / WIM-24325.MH
WIM 325
|
WESTPOINT | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
AC186i.3-5.3 / AC186i.3-5.3 W
Logacool
|
Buderus | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC186i.3-5,3 / AC186i.3-5,3 WB
Logacool
|
Buderus | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC-5,3 MS E+ / AC186i.3-2,6 W + AC186i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
WIMO-18325.MH / WIM-18325.MH
WIM 325
|
WESTPOINT | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WIM-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12326.MH / WIM-12326.MH
WIM 326
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
AC176iP-2,6 / AC176iP-2,6 W
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W S
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
WIMO-09325.MH / WIM-09325.MH
WIM 325
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
AC186i.3-4,1 / AC186i.3-4,1 W
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
AC186i.3-4,1 / AC186i.3-4,1 WB
Logacool
|
Buderus | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
AC176i.3-2,6 / AC176i.3-2,6 W
Logacool
|
Buderus | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
WIMO-18324.MH / WIM-18324.MH
WIM 324
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18326.MH / WIM-18326.MH
WIM 326
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
AC176i.3-5,3 / AC176i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WIMO-18322.MH/WIM-18322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WITO-18322.MH/WIT-18322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AC176i.3-7,0 / AC176i.3-7,0 W
Logacool
|
Buderus | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24326.MH / WIM-24326.MH
WIM 326
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AC176i.3-3,5 / AC176i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
WITO-12322.MH/WIT-12322.MH
WIT
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
WIMO-12325.MH / WIM-12325.MH
WIM 325
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
AC176iP-3,5 / AC176iP-3,5 W
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W S
AC176iP
|
Buderus | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
N160Xi R15/UO160Xo R15
Nevo
|
Rotenso | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
N120Xi R15/UO120Xo R14
Nevo
|
Rotenso | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
N140Xi R15/UO140Xo R15
Nevo
|
Rotenso | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
J140Xi R14/UO140Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
J160Xi R14/UO160Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
AC166i.2-5,3 / AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-3,5 / AC166i.2-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC166i.2-3,5 / AC166i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC-5,3 MS / AC166i-2,6 MS CN + AC166i-2,6 MS CN
Logacool
|
Buderus | Console | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 |