Filters · 3 active
Manufacturer:
BOSCH
SAMSUNG
AIRCLASS
(2)
AIRWELL
(65)
ATLANTIC
(27)
AUX
(66)
BRYANT
(6)
Buderus
(20)
CARRIER
(101)
CIAT
(42)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(563)
EQUATION
(5)
FUJI ELECTRIC
(150)
FUJITSU
(353)
Fujitsu Atlantic
(180)
GENERAL
(188)
GREE
(95)
GSS
(4)
HAIER
(451)
HEC
(5)
HEIWA
(5)
HISENSE
(213)
HITACHI
(116)
IVT
(1)
Inventor
(114)
KAYSUN
(66)
LG
(316)
MIDEA
(644)
MITSUBISHI ELECTRIC
(497)
Mitsubishi Heavy Industries
(284)
NORD
(40)
Nobu
(8)
PANASONIC
(197)
RIELLO
(45)
Rotenso
(8)
THERMOR
(43)
TOSHIBA
(193)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(9)
YORK
(37)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
AC071BXAPKG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
AC071BXAPNG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC120BXAPNG / AC120BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 4.00 | -25° | 12.10 | 9.50 | |
|
AC140BXAPNG / AC140BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.63 | -25° | 13.40 | 9.50 | |
|
AC071BXAPKG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC071BXAPNG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC052RXADKG/AC052RN4DKG
CAC
|
SAMSUNG | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.30 | 4.03 | -20° | 5.00 | 2.60 | |
|
AC035BXAPKG/AC035BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | 3.81 | -25° | 3.50 | 2.30 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
AC120BXAPNG / AC120BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.77 | -25° | 12.10 | 9.20 | |
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
AC100RXADKG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.61 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.69 | -20° | 10.00 | 5.30 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.55 | -20° | 10.00 | 5.30 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
AJ120HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.45 | 3.61 | -10° | 12.00 | 8.37 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
AJ100HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.26 | 4.28 | 3.87 | -10° | 9.80 | 7.91 | |
|
CL5001L 53 E / CL5001iU D 53 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
CL5001L 70 E / CL5000iL CF 70 E
Climate 5001 L
|
BOSCH | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
CL6001i 70 E / CL6001iU W 70 E
Climate 6000i
|
BOSCH | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
AC071BXAPKG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
AC071BXAPNG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
AJ070HCJ2KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.16 | 4.17 | -10° | 7.00 | 5.65 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 |