Filters · 3 active
Manufacturer:
BOSCH
SAMSUNG
AIRCLASS
(2)
AIRWELL
(52)
ATLANTIC
(17)
AUX
(52)
BRYANT
(2)
Buderus
(18)
CARRIER
(89)
CIAT
(31)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(676)
EQUATION
(3)
FUJI ELECTRIC
(93)
FUJITSU
(252)
Fujitsu Atlantic
(118)
GENERAL
(120)
GREE
(56)
GSS
(2)
HAIER
(368)
HEC
(0)
HEIWA
(3)
HISENSE
(167)
HITACHI
(132)
IVT
(4)
Inventor
(94)
KAYSUN
(54)
LG
(228)
MIDEA
(505)
MITSUBISHI ELECTRIC
(467)
Mitsubishi Heavy Industries
(365)
NORD
(30)
Nobu
(4)
PANASONIC
(192)
RIELLO
(32)
Rotenso
(8)
THERMOR
(21)
TOSHIBA
(222)
Viessmann
(16)
Vulcano
(10)
WESTPOINT
(10)
YORK
(29)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.90 | 4.38 | -25° | 5.00 | 4.10 | |
|
AC071BXAPKG/AC071BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.80 | 4.52 | -25° | 7.10 | 5.50 | |
|
AC071BXAPNG/AC071BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.80 | 4.52 | -25° | 7.10 | 5.50 | |
|
AC052BXAPKG/AC052BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.58 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.30 | 4.60 | 3.70 | -25° | 5.00 | 3.90 | |
|
AC100BXAPKG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
AC100BXAPNG/AC100BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.44 | -25° | 10.00 | 8.50 | |
|
AC071BXAPKG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
AC071BXAPNG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
AC071BXAPKG/AC071BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.08 | -25° | 7.10 | 5.00 | |
|
AC071BXAPNG/AC071BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.08 | -25° | 7.10 | 5.00 | |
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC120BXAPNG / AC120BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 4.00 | -25° | 12.10 | 9.50 | |
|
AC120BXAPNG / AC120BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 4.13 | -25° | 12.10 | 9.50 | |
|
AC100BXAPKG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC100BXAPNG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC140BXAPNG / AC140BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.63 | -25° | 13.40 | 9.50 | |
|
AC140BXAPNG / AC140BN4PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.70 | 3.97 | -25° | 13.40 | 9.50 | |
|
AC071BXAPKG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC071BXAPNG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC052RXADKG/AC052RN4DKG
CAC
|
SAMSUNG | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.30 | 4.03 | -20° | 5.00 | 2.60 | |
|
AJ050TXJ2KG / AR70F09CAAW / AR70F09CAAW
FJM
|
SAMSUNG | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.54 | 4.64 | 4.38 | -10° | 5.00 | 4.21 | |
|
CL7000M 53/2 E /CL5000iM CN 26 E +CL5000iM CN 26 E
Climate 7000 M
|
BOSCH | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
AC120BXAPNG / AC120BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.77 | -25° | 12.10 | 9.20 | |
|
CL7000M 79/3 E / CL7000iU W 53 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 7.10 | 5.60 | |
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
CL6102i 70 HE / CL6102i W 70 HE
Climate 6102i
|
BOSCH | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 7.00 | 5.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
AC100RXADKG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.61 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.69 | -20° | 10.00 | 5.30 | |
|
CL5001L 70 E / CL5001iU D 70 E
Climate 5001 L
|
BOSCH | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
CL7000i 53 E / CL7000iU W 53 E
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 ES
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
CL7000i 53 E / CL7000iU W 53 EB
Climate 7000i
|
BOSCH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 5.00 | 4.50 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
CL7000M 53/2 E / CL7000iU W 26 E + CL7000iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.88 | -10° | 5.30 | 4.30 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AC052BXAPKG/AC052BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -25° | 5.00 | 3.90 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.55 | -20° | 10.00 | 5.30 | |
|
AJ120HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.45 | 3.61 | -10° | 12.00 | 8.37 | |
|
CL7100i 50 HE / CL7100i W 50 HE
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HES
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
CL7100i 50 HE / CL7100i W 50 HEB
Climate 7100i
|
BOSCH | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.00 | 4.20 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
AJ100HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.26 | 4.28 | 3.87 | -10° | 9.80 | 7.91 |