Filters · 3 active
Manufacturer:
HITACHI
SAMSUNG
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(0)
AUX
(10)
BOSCH
(15)
BRYANT
(0)
Buderus
(2)
CARRIER
(22)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(230)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(88)
HEC
(0)
HEIWA
(0)
HISENSE
(34)
IVT
(0)
Inventor
(15)
KAYSUN
(26)
LG
(64)
MIDEA
(96)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(10)
Nobu
(0)
PANASONIC
(42)
RIELLO
(11)
Rotenso
(3)
THERMOR
(5)
TOSHIBA
(45)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
RAS-6HVRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HRC2E
UTOPIA PRIME
|
HITACHI | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.73 | 4.40 | -20° | 14.00 | 14.20 | |
|
AC071BXAPKG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
AC071BXAPNG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
AC100BXAPKG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
AC100BXAPNG/AC100BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.40 | 4.07 | -25° | 10.00 | 7.80 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
AC120BXAPNG / AC120BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 4.00 | -25° | 12.10 | 9.50 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
AC140BXAPNG / AC140BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.63 | -25° | 13.40 | 9.50 | |
|
RAS-4HNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.60 | 4.43 | 3.79 | -20° | 10.00 | 8.70 | |
|
RAS-5HNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.52 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
RAS-4HVRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.44 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-4HVNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-5HVRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.17 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-5HRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.89 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
RAS-4HNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.96 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
RAS-3HVRC3 / RPI-3.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.92 | 3.84 | -25° | 7.10 | 6.00 | |
|
RAC-70NPD / RAD-70PPD
RAC-NPE(D)
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.09 | 3.64 | -15° | 7.00 | 5.20 | |
|
RAC-50NPE / RAD-50RPE
RAC-NPE(D)
|
HITACHI | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.01 | 3.82 | -15° | 5.00 | 4.60 | |
|
RAC-60NPE / RAD-60RPE
RAC-NPE(D)
|
HITACHI | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.21 | 4.01 | 3.80 | -15° | 6.00 | 4.60 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
RPIL-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.05 | 3.74 | -15° | 6.90 | 6.00 | |
|
AC140RXADNG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.44 | -20° | 13.40 | 8.40 | |
|
AC140RXADKG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.34 | -20° | 13.40 | 8.40 | |
|
RAC-VJ50NHAE / RAD-VJ50RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.01 | 3.80 | -10° | 5.00 | 4.30 | |
|
AC071RXADKG/AC071RNMDKG
CAC
|
SAMSUNG | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -20° | 6.80 | 3.70 | |
|
RAC-VJ60NHAE / RAD-VJ60RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.02 | 3.80 | -10° | 6.00 | 4.60 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
RPIH-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -15° | 8.50 | 6.50 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RPIH-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 3.00 | -15° | 10.10 | 8.20 | |
|
RAC-VJ70NHAE / RAD-VJ70RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.02 | 3.64 | -10° | 7.00 | 5.30 | |
|
RAS-5HNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
AC100RXADKG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.20 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.27 | -20° | 10.00 | 5.20 |