Filters · 3 active
Manufacturer:
Inventor
SAMSUNG
AIRCLASS
(0)
AIRWELL
(57)
ATLANTIC
(17)
AUX
(66)
BOSCH
(55)
BRYANT
(5)
Buderus
(16)
CARRIER
(89)
CIAT
(34)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(475)
EQUATION
(2)
FUJI ELECTRIC
(109)
FUJITSU
(287)
Fujitsu Atlantic
(140)
GENERAL
(139)
GREE
(62)
GSS
(3)
HAIER
(401)
HEC
(5)
HEIWA
(4)
HISENSE
(202)
HITACHI
(99)
IVT
(0)
KAYSUN
(61)
LG
(294)
MIDEA
(519)
MITSUBISHI ELECTRIC
(443)
Mitsubishi Heavy Industries
(281)
NORD
(36)
Nobu
(7)
PANASONIC
(188)
RIELLO
(37)
Rotenso
(8)
THERMOR
(32)
TOSHIBA
(203)
Viessmann
(21)
Vulcano
(14)
WESTPOINT
(3)
YORK
(35)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AC052BXAPKG/AC052BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.67 | -25° | 5.00 | 4.00 | |
|
U7iRS-30/V7iDI-30WiFiR
Ducted R32
|
Inventor | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
AC100RXADKG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.61 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.69 | -20° | 10.00 | 5.30 | |
|
U7iRS-24/V7iDI-24WiFiR
Ducted R32
|
Inventor | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.55 | -20° | 10.00 | 5.30 | |
|
U7RS-12/V7iDI-12WiFiR
Ducted R32
|
Inventor | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
AJ120HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ035HEAPKG / AJ035HEAPKG
FJM
|
SAMSUNG | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.45 | 3.61 | -10° | 12.00 | 8.37 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
U7RS-18/V7iDI-18WiFiR
Ducted R32
|
Inventor | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
U7RS-36/V7iDI-36WiFiR
Ducted R32
|
Inventor | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7RT-60/V7DI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7iDI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
V7FSO-24/V7FSI-24
Floor Standing Cabinet R32
|
Inventor | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
AC071BXAPKG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
AC071BXAPNG/AC071BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.32 | -25° | 7.10 | 3.90 | |
|
U7RS-12/V7iCRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
U7RS-42/V7iDI-42WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
U7RS-18/V7DI-18WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
U7RS-36/V7DI-36WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
AC140RXADNG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.44 | -20° | 13.40 | 8.40 | |
|
AC140RXADKG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.34 | -20° | 13.40 | 8.40 | |
|
U7iRS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U7RS-42/V7DI-42WiFiR
Ducted R32
|
Inventor | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
U7RS-12/V7DI-12WiFiR
Ducted R32
|
Inventor | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
AR70F24C1AWN/AR70F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 | |
|
AR60F24C1AWN/AR60F24C1AWX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.36 | -11° | 6.50 | 4.10 |