Filters · 3 active
Manufacturer:
FUJI ELECTRIC
TOSHIBA
AIRCLASS
(0)
AIRWELL
(43)
ATLANTIC
(19)
AUX
(42)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(59)
CIAT
(32)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(239)
EQUATION
(4)
FUJITSU
(173)
Fujitsu Atlantic
(85)
GENERAL
(81)
GREE
(35)
GSS
(4)
HAIER
(349)
HEC
(5)
HEIWA
(3)
HISENSE
(126)
HITACHI
(43)
IVT
(0)
Inventor
(78)
KAYSUN
(46)
LG
(156)
MIDEA
(361)
MITSUBISHI ELECTRIC
(148)
Mitsubishi Heavy Industries
(87)
NORD
(19)
Nobu
(6)
PANASONIC
(60)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(66)
THERMOR
(41)
Viessmann
(8)
Vulcano
(14)
WESTPOINT
(0)
YORK
(32)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM1102ATW-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.85 | -15° | 9.50 | 8.40 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
ROG30KBTB/RDG30KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
ROG30KBTB/RDG30KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
RAV-GM902ATW-E/RAV-HM901FT-E
DI
|
TOSHIBA | Floor standing | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.00 | 3.70 | -15° | 8.00 | 6.30 | |
|
ROG36KBTB/RDG36KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG14KBTB/RDG14KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
ROG24KLTA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLCA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.22 | 3.92 | 3.61 | -15° | 9.50 | 8.30 | |
|
RAV-GP1401AT8-E1/RAV-HM1401BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.98 | 3.83 | -20° | 12.50 | 11.80 | |
|
ROG12KBTB/RDG12KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROG90LRLA/RDG90LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
RAV-GM1102AT8W-E/RAV-HM1101FT-E
DI 3ph
|
TOSHIBA | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.92 | 3.64 | -15° | 9.50 | 8.30 | |
|
RAV-GM1402ATW-E/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 3.92 | 3.66 | -15° | 12.10 | 8.40 | |
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
RAV-GM402ATP-E/RAV-HM401SDTY-E
DI
|
TOSHIBA | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.00 | 4.12 | -15° | 3.60 | 2.70 | |
|
ROG30KBTB/RYG30KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG22KBTB/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
RAV-GM1602AT8W-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.96 | 3.43 | -15° | 14.00 | 8.40 | |
|
ROG24KBTA3/RSG12KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
ROG14KVCA/RGG14KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.10 | 4.00 | 3.70 | -15° | 4.20 | 4.20 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
ROG72LRLA/RDG72LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
ROG30KATA/RDG30KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG45KBTB/RDG45KHTA
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG45KBTB/RDG45KHTB
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTB
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTA
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.32 | 3.86 | 3.24 | -10° | 20.00 | 11.40 | |
|
ROG36KATA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG30KATA/RCG30KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
RAV-GM802ATW-E/RAV-HM801SDTY-E
DI
|
TOSHIBA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 4.00 | 3.44 | -15° | 6.70 | 5.10 | |
|
RAV-GM1402ATW-E/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.90 | 3.29 | -15° | 12.10 | 8.30 | |
|
RAV-GM802ATW-E/RAV-HM801FT-E
DI
|
TOSHIBA | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 4.00 | 3.11 | -15° | 6.70 | 5.10 | |
|
RAV-GV1101ATP-E/RAV-HM1101KRTP-E
DIC
|
TOSHIBA | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.03 | -15° | 9.50 | 7.60 | |
|
RAV-GM1402AT8W-E/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 3.84 | 3.71 | -15° | 12.10 | 8.40 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.36 | 3.95 | 3.33 | -10° | 23.50 | 12.30 | |
|
ROG36KATA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
RAV-GV1101ATP-E/RAV-HM1101UTP-E
DIC
|
TOSHIBA | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.23 | -15° | 9.50 | 7.60 | |
|
ROG24KATA/RDG24KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG24KATA/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
RAV-GV801ATP-E/RAV-HM801BTP-E
DIC
|
TOSHIBA | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 4.00 | 3.00 | -15° | 6.70 | 4.80 |