Filters · 3 active
Manufacturer:
Fujitsu Atlantic
TOSHIBA
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(5)
AUX
(10)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(31)
CIAT
(16)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(247)
EQUATION
(0)
FUJI ELECTRIC
(57)
FUJITSU
(154)
GENERAL
(73)
GREE
(10)
GSS
(0)
HAIER
(172)
HEC
(0)
HEIWA
(0)
HISENSE
(43)
HITACHI
(66)
IVT
(0)
Inventor
(35)
KAYSUN
(36)
LG
(85)
MIDEA
(180)
MITSUBISHI ELECTRIC
(269)
Mitsubishi Heavy Industries
(294)
NORD
(8)
Nobu
(0)
PANASONIC
(88)
RIELLO
(17)
Rotenso
(8)
SAMSUNG
(27)
THERMOR
(3)
Viessmann
(8)
Vulcano
(1)
WESTPOINT
(0)
YORK
(16)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP1101AT-E/RAV-HM1101UT-E
SDI
|
TOSHIBA | Cassette | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.25 | 5.03 | 5.14 | -27° | 10.00 | 9.20 | |
|
RAV-GP1401AT-E1/RAV-HM1401UT-E
SDI
|
TOSHIBA | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.87 | 5.00 | 4.61 | -27° | 12.50 | 9.60 | |
|
RAV-GP1101AT-E/RAV-HM1101UTP-E
SDI
|
TOSHIBA | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.76 | 4.79 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101FT-E
SDI
|
TOSHIBA | Floor standing | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.40 | 4.06 | -27° | 10.00 | 9.20 | |
|
RAV-GP1401AT-E1/RAV-HM1401UTP-E
SDI
|
TOSHIBA | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 4.74 | 4.36 | -27° | 12.50 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401FT-E
SDI
|
TOSHIBA | Floor standing | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.49 | 4.38 | 3.00 | -27° | 12.30 | 9.60 | |
|
RAV-GP1101AT-E/RAV-HM1101CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.58 | 4.75 | 4.71 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101BTP-E
SDI
|
TOSHIBA | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.19 | 4.30 | 4.10 | -27° | 10.00 | 9.20 | |
|
RAV-GP1101AT-E/RAV-HM1101KRTP-E
SDI
|
TOSHIBA | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.42 | 3.58 | -27° | 10.00 | 9.20 | |
|
RAV-GP1401AT-E1/RAV-HM1401CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.99 | 4.73 | 3.90 | -27° | 12.50 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401BTP-E
SDI
|
TOSHIBA | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.28 | 3.86 | -27° | 12.50 | 9.60 | |
|
RAV-GP1101AT8-E/RAV-HM1101CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.23 | 4.46 | -20° | 10.00 | 11.60 | |
|
RAV-GM1102ATW-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.40 | 3.92 | -15° | 9.50 | 8.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.91 | -15° | 9.50 | 8.00 | |
|
RAV-GP1101AT8-E/RAV-HM1101UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.32 | 4.38 | 4.65 | -20° | 10.00 | 9.50 | |
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
RAV-GP1401AT8-E1/RAV-HM1401UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.35 | 4.37 | 4.11 | -20° | 12.50 | 9.50 | |
|
RAV-GP1101AT8-E/RAV-HM1101FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.14 | 4.02 | 4.04 | -20° | 10.00 | 10.80 | |
|
RAV-GP1401AT8-E1/RAV-HM1401CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.21 | 4.02 | -20° | 12.50 | 11.80 | |
|
RAV-GP1601AT8-E/RAV-HM1601UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.99 | 4.38 | 3.74 | -20° | 14.00 | 9.50 | |
|
RAV-GM1402ATW-E/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.79 | -15° | 12.10 | 8.00 | |
|
RAV-GM1102AT8W-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.46 | 4.29 | 3.95 | -15° | 9.50 | 8.00 | |
|
RAV-GP1401AT8-E1/RAV-HM1401FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.02 | 3.00 | -20° | 12.50 | 11.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.19 | 4.06 | -20° | 10.00 | 10.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101KRTP-E
SDI 3ph
|
TOSHIBA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.22 | 3.45 | -20° | 10.00 | 10.80 | |
|
AOYG36KBTB/ARXG36KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ARXG36KHTAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
RAV-GM1602ATW-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.39 | -15° | 14.00 | 8.00 | |
|
AOYG36KBTB/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.21 | 3.75 | -15° | 9.50 | 8.70 | |
|
RAV-GP1601AT8-E/RAV-HM1601CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.21 | 3.72 | -20° | 14.00 | 12.00 | |
|
RAV-GM1102AT8W-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.15 | 4.29 | 3.97 | -15° | 9.50 | 8.00 | |
|
RAV-GM1602ATW-E/RAV-HM1601CTP-E
DI
|
TOSHIBA | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.30 | 3.37 | -15° | 14.00 | 8.00 | |
|
AOYG30KBTB/AUXG30KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
RAV-GM1602AT8W-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.38 | 3.44 | -15° | 14.00 | 8.00 | |
|
AOYG36KBTB/ARXH36KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ARXH36KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 | |
|
AOYG45KBTB/AUXG45KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOYG45KRTA/AUXG45KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
RAV-GM1402AT8W-E/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.91 | 4.30 | 3.83 | -15° | 12.10 | 8.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.28 | 3.74 | -15° | 12.10 | 8.00 | |
|
AOYG36KBTB/AUXG36KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
RAV-GM1601ATP-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.85 | -15° | 9.50 | 8.40 | |
|
RAV-GM1102ATW-E/RAV-HM1101KRTP-E
DI
|
TOSHIBA | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.26 | -15° | 9.50 | 8.00 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
RAV-GM1602AT8W-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.22 | 3.41 | -15° | 14.00 | 8.00 |