Filters · 3 active
Manufacturer:
ATLANTIC
Viessmann
AIRCLASS
(4)
AIRWELL
(84)
AUX
(68)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(575)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(103)
GSS
(4)
HAIER
(528)
HEC
(5)
HEIWA
(8)
HISENSE
(340)
HITACHI
(163)
IVT
(10)
Inventor
(147)
KAYSUN
(70)
LG
(351)
MIDEA
(839)
MITSUBISHI ELECTRIC
(613)
Mitsubishi Heavy Industries
(400)
NORD
(49)
Nobu
(8)
PANASONIC
(316)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(204)
THERMOR
(56)
TOSHIBA
(305)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UI 5,3 kW MURAO PREMIUM BLANC & UE MONO 5,3 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 4.00 | -10° | 5.30 | 4.70 | |
|
UI 5,3 kW MURAO PREMIUM NOIR & UE MONO 5,3 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 4.00 | -10° | 5.30 | 4.70 | |
|
AS 009 JDB.UI/ 1U 009 JD.UE
Kazendo
|
ATLANTIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 5.10 | 4.80 | -10° | 2.60 | 2.60 | |
|
Vitoclima100-SPROIDHAA100MFP088/Vitoclima100-SPROOFAA100MFP088
Ducted
|
Viessmann | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS 012 JDB.UI/ 1U 012 JD.UE
Kazendo
|
ATLANTIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.75 | 4.70 | 4.70 | -10° | 3.50 | 2.65 | |
|
Vitoclima100-SIDHAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Ducted
|
Viessmann | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
2U 018 NBB.UE/AS 009 JDB.UI/AS 012 JDB.UI
Super Match Multi
|
ATLANTIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.71 | -10° | 4.60 | 4.00 | |
|
UI 4,2 kW MURAO SMART BLANC & UE MONO 4,2 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 4.00 | 3.60 | |
|
UI 4,2 kW MURAO PREMIUM BLANC & UE MONO 4,2 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 4.00 | 3.60 | |
|
UI 4,2 kW MURAO PREMIUM NOIR & UE MONO 4,2 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 4.00 | 3.60 | |
|
UI 2,6 kW MURAO PREMIUM BLANC & UE MONO 2,6 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
UI 2,6 kW MURAO PREMIUM NOIR & UE MONO 2,6 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
Vitoclima100-SIDHAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ducted
|
Viessmann | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
UI 3,2 kW MURAO PREMIUM BLANC & UE MONO 3,2 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.71 | -10° | 3.20 | 2.80 | |
|
UI 3,2 kW MURAO PREMIUM NOIR & UE MONO 3,2 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.71 | -10° | 3.20 | 2.80 | |
|
UI 2,1 kW MURAO SMART BLANC & UE MONO 2,1 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM BLANC & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM NOIR & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
Vitoclima100-SICNAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Console
|
Viessmann | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
Vitoclima100-SIFCAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ceiling suspended
|
Viessmann | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
Vitoclima100-SIC8AA100MFA035/Vitoclima100-SPROOFAA100MFP035
Cassette
|
Viessmann | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
AC 018 DB.UI/1U 018 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.00 | 3.71 | -10° | 5.20 | 4.40 | |
|
Vitoclima100-SPROIC8AA100MFP088/Vitoclima100-SPROOFAA100MFP105
Cassette
|
Viessmann | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
UI 2,7 kW MURAO SMART BLANC & UE MONO 2,7 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
AS 018 NBB.UI/1U 018 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.00 | -10° | 5.20 | 4.60 | |
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ducted
|
Viessmann | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
AS 012 NBB.UI/1U 012 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.81 | -10° | 3.50 | 2.80 | |
|
UI 3,6 kW MURAO SMART BLANC & UE MONO 3,6 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 3.30 | 2.80 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100MFP105
Cassette
|
Viessmann | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
Vitoclima100-SIC8AA100MFA052/Vitoclima100-SPROOFAA100MFP052
Cassette
|
Viessmann | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
AC 036 DB.UI/1U 036 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.23 | -10° | 9.50 | 7.00 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100TFP105
Cassette
|
Viessmann | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
Vitoclima100-SIFCAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ceiling suspended
|
Viessmann | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
Vitoclima100-SIC8AA100MFA070/Vitoclima100-SPROOFAA100MFP070
Cassette
|
Viessmann | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS 018 JDB.UI/ 1U 018 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
Vitoclima 050-S IWAA050MFA052/Vitoclima 050-S OWAA050MFA052
Wall mounted
|
Viessmann | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
AS 009 NBB.UI/1U 009 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
Vitoclima 050-S IWAA050MFA026/Vitoclima 050-S OWAA050MFA026
Wall mounted
|
Viessmann | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
AC 048 DB.UI/1U 048 DC.UE
R32 Super Match Plus - Convertible
|
ATLANTIC | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.21 | 12.40 | 8.00 | ||
|
Vitoclima 050-S IWAA050MFA035/Vitoclima 050-S OWAA050MFA035
Wall mounted
|
Viessmann | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
AS 012 DBB.UI/ 1U 012 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.71 | -10° | 3.60 | 3.20 |