Filters · 3 active
Manufacturer:
BRYANT
Viessmann
YORK
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Vulcano
(16)
WESTPOINT
(22)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
Vitoclima100-SPROIDHAA100MFP088/Vitoclima100-SPROOFAA100MFP088
Ducted
|
Viessmann | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
Vitoclima100-SIDHAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Ducted
|
Viessmann | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
YHKF09XEEDMH-RY / YHKF09YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.30 | 4.60 | 4.60 | -10° | 2.60 | 2.40 | |
|
Vitoclima100-SIDHAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ducted
|
Viessmann | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
YUKF55BYOEBMO-1/YFKF55BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -15° | 15.50 | 11.90 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
YUKF36BYEEBMO-1/YFKF36BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
Vitoclima100-SICNAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Console
|
Viessmann | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
YUKF30BYEEBMO-1/YEKF30BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
YUKF55BYOEBMO-1/YEKF55BXOEBM-R1
Grande Duct R32
|
YORK | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -15° | 15.30 | 12.50 | |
|
Vitoclima100-SIFCAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ceiling suspended
|
Viessmann | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
YHKF12XEEDMH-RY / YHKF12YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
Vitoclima100-SIC8AA100MFA035/Vitoclima100-SPROOFAA100MFP035
Cassette
|
Viessmann | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
YUKF18BYEEBMO-1/YEKF18BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
YUKF36BYEEBMO-1/YEKF36BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
YUKF42BYEEBMO-1/YEKF42BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -15° | 12.10 | 9.50 | |
|
Vitoclima100-SPROIC8AA100MFP088/Vitoclima100-SPROOFAA100MFP105
Cassette
|
Viessmann | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
YUKF30BYEEBMO-1/YKKF30BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
YUKF12BYEEBMO-1/YEKF12BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ducted
|
Viessmann | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
YUKF36BYOEBMO-1/YEKF36BXOEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
YUKF12BYEEBMO-1/YKKF12BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100MFP105
Cassette
|
Viessmann | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
YUKF36BYEEBMO-1/YKKF36BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
YUKF24BYEEBMO-1/YEKF24BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
Vitoclima100-SIC8AA100MFA052/Vitoclima100-SPROOFAA100MFP052
Cassette
|
Viessmann | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
YUKF36BYOEBMO-1/YFKF36BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
YUKF48BYOEBMO-1/YFKF48BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -15° | 14.00 | 11.20 | |
|
YUKF55BYOEBMO-1/YKKF55BXOEBM-R1
Grande Cassette R32
|
YORK | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -15° | 15.30 | 11.90 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100TFP105
Cassette
|
Viessmann | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
Vitoclima100-SIFCAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ceiling suspended
|
Viessmann | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
YUKF48BYOEBMO-1/YEKF48BXOEBM-R1
Grande Duct R32
|
YORK | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -15° | 14.00 | 11.50 | |
|
Vitoclima100-SIC8AA100MFA070/Vitoclima100-SPROOFAA100MFP070
Cassette
|
Viessmann | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
YUKF24BYEEBMO-1/YFKF24BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
YUKF42BYEEBMO-1/YKKF42BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -15° | 12.10 | 9.50 | |
|
42BRF018B8S*/38BRF018B8S*
Wall mounted
|
BRYANT | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
Vitoclima 050-S IWAA050MFA052/Vitoclima 050-S OWAA050MFA052
Wall mounted
|
Viessmann | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
YUKF48BYOEBMO-1/YKKF48BXOEBM-R1
Grande Cassette R32
|
YORK | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 14.00 | 11.00 | |
|
YUKF18BYEEBMO-1/YFKF18BXEEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
YHKF18YEEBMJO-X/YHKF18XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
YHKF18YEEBMJO-T/YHKF18XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
42BRF009B8S-1/38BRF009B8S-1
Wall mounted
|
BRYANT | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
Vitoclima 050-S IWAA050MFA026/Vitoclima 050-S OWAA050MFA026
Wall mounted
|
Viessmann | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
YUKF18BYEEBMO-1/YKKF18BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
YHKF18XEEBMH-RY / YHKF18YEEBMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.65 | -10° | 5.30 | 4.10 |