Filters · 3 active
Manufacturer:
FUJI ELECTRIC
Viessmann
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(0)
AUX
(10)
BOSCH
(15)
BRYANT
(0)
Buderus
(2)
CARRIER
(22)
CIAT
(11)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(230)
EQUATION
(0)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(88)
HEC
(0)
HEIWA
(0)
HISENSE
(34)
HITACHI
(41)
IVT
(0)
Inventor
(15)
KAYSUN
(26)
LG
(64)
MIDEA
(96)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(10)
Nobu
(0)
PANASONIC
(42)
RIELLO
(11)
Rotenso
(3)
SAMSUNG
(23)
THERMOR
(5)
TOSHIBA
(45)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ROG09KBTB/RDG09KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG22KBTB/RDG22KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.87 | -15° | 6.00 | 4.80 | |
|
Vitoclima100-SPROIDHAA100MFP088/Vitoclima100-SPROOFAA100MFP088
Ducted
|
Viessmann | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
Vitoclima100-SIDHAA100MFA070/Vitoclima100-SPROOFAA100MFP070
Ducted
|
Viessmann | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.80 | -10° | 7.10 | 5.60 | |
|
Vitoclima100-SIDHAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Ducted
|
Viessmann | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
ROG36KBTB/RDG36KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RDG36KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.35 | -15° | 9.50 | 8.70 | |
|
ROG18KBTB/RDG18KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -15° | 5.20 | 4.40 | |
|
ROG12KBTB/RDG12KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.10 | -15° | 3.50 | 3.40 | |
|
Vitoclima100-SIDHAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.72 | -10° | 5.30 | 4.30 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ducted
|
Viessmann | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
ROG24KBTB/RDG24KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
ROG18KBTB/RDG18KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.70 | -15° | 5.20 | 4.40 | |
|
ROG30KBTB/RDG30KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
ROG30KBTB/RDG30KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
ROG22KBTB/RDG22KMLB
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
ROG24KBTB/RDG24KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
ROG36KBTB/RDG36KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
ROG14KBTB/RDG14KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
Vitoclima100-SPROIDHAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ducted
|
Viessmann | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
ROG12KBTB/RDG12KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROG90LRLA/RDG90LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
ROG72LRLA/RDG72LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
ROG30KATA/RDG30KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG45KBTB/RDG45KHTA
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG45KBTB/RDG45KHTB
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTB
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTA
RD**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
ROG36KATA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG24KATA/RDG24KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.75 | -15° | 6.80 | 5.40 | |
|
ROG45KBTB/RDG45KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
ROG14KBTB/RDG14KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
ROG54KBTB/RDG54KHTA
RD**K
|
FUJI ELECTRIC | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
ROG54KRTA/RDG54KHTA
RD**K
|
FUJI ELECTRIC | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
ROG54KRTA/RDG54KHTB
RD**K
|
FUJI ELECTRIC | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
ROG54KBTB/RDG54KHTB
RD**K
|
FUJI ELECTRIC | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
ROG54KBTB/RDG54KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.85 | 3.98 | 13.40 | 9.50 | ||
|
ROG54KRTA/RDG54KHTAP
RDG**K
|
FUJI ELECTRIC | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.85 | 3.98 | 13.40 | 9.50 | ||
|
ROG09KATA/RDG09KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
ROG12KATA/RDG12KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
ROG18KATA/RDG18KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
ROG22KATA/RDG22KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
ROG22KATA/RDG22KMLB
RDG**K
|
FUJI ELECTRIC | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
ROG14KATA/RDG14KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
ROG45KBTB/RDG45KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 | ||
|
ROG45KRTA/RDG45KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.63 | 3.52 | 12.10 | 9.20 |