Filters · 3 active
Manufacturer:
CIAT
HEIWA
WESTPOINT
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
WIMO-09326.MH / WIM-09326.MH
WIM 326
|
WESTPOINT | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
WIMO-24325.MH / WIM-24325.MH
WIM 325
|
WESTPOINT | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
HMIP2-50W-EUV1 / HMEP2-50-EUV1
HYOKO2
|
HEIWA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.10 | 4.10 | |
|
WIMO-18325.MH / WIM-18325.MH
WIM 325
|
WESTPOINT | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
38HM18VS8C-2/42HY09VS8C*
Ducted
|
CIAT | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 4.29 | -10° | 5.80 | 4.60 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WIM-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12326.MH / WIM-12326.MH
WIM 326
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
HMIP2-70W-EUV1 / HMEP2-70-EUV1
HYOKO2
|
HEIWA | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.55 | -10° | 6.50 | 5.00 | |
|
42HG09JS8C-1/38HG09JS8C-1
Wall mounted
|
CIAT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.46 | -10° | 2.64 | 2.40 | |
|
WIMO-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
WIMO-09325.MH / WIM-09325.MH
WIM 325
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
42HE18JS8C*/38HE18JS8C*
Wall mounted
|
CIAT | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.40 | 3.77 | -10° | 5.20 | 4.30 | |
|
42HU36VDS8C/38HU36VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
42HE24JS8C*/38HE24JS8C*
Wall mounted
|
CIAT | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
WIMO-18324.MH / WIM-18324.MH
WIM 324
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18326.MH / WIM-18326.MH
WIM 326
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18322.MH/WIM-18322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WITO-18322.MH/WIT-18322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
HMIP2-35W-EUV1 / HMEP2-35-EUV1
HYOKO2
|
HEIWA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.51 | 3.20 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24326.MH / WIM-24326.MH
WIM 326
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HC18VDS8C*/38HU18VDS8C*
Console
|
CIAT | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
42HG12JS8C-1/38HG12JS8C-1
Wall mounted
|
CIAT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
WITO-12322.MH/WIT-12322.MH
WIT
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
WIMO-12325.MH / WIM-12325.MH
WIM 325
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
HMIP2-25W-EUV1 / HMEP2-25-EUV1
HYOKO2
|
HEIWA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.41 | -10° | 2.70 | 2.70 | |
|
42HY18VDS8C/38HU18VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
42HK30VDS8C/38HU30VD8SC
Cassette
|
CIAT | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
42HY36VDS8C/38HU36VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
42HY60VDS8C/38HU60VDT8C
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
42HY42VDS8C*/38HU42VD8C*
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
42HK12VDS8C/38HU12VDS8C
Cassette
|
CIAT | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
42HY48VDS8C/38HU48VDT8C
Ducted
|
CIAT | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
42HY12VDS8C/38HU12VDS8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
WIZO-24225.MH / WIZ-24225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.90 | -10° | 7.10 | 5.60 | |
|
42HY36VDS8C/38HU36VDT8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
42HK36VDS8C/38HU36VDS8C
Cassette
|
CIAT | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
42HU36VDS8C/38HU36VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
42HY24VDS8C/38HU24VDS8C
Ducted
|
CIAT | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.14 | -10° | 7.10 | 5.40 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HU48VDS8C/38HU48VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 | ||
|
42HK36VDS8C/38HU36VDT8C
Cassette
|
CIAT | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
42HU18VDS8C/38HU18VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
42HK60VDS8C/38HU60VDT8C
Cassette
|
CIAT | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.21 | 15.00 | 11.80 |