Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(5)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(5)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(1)
DAIKIN
(16)
EQUATION
(0)
FUJI ELECTRIC
(7)
FUJITSU
(15)
Fujitsu Atlantic
(6)
GENERAL
(12)
GREE
(7)
GSS
(1)
HAIER
(12)
HEC
(0)
HEIWA
(1)
HISENSE
(1)
HITACHI
(7)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(7)
MIDEA
(7)
MITSUBISHI ELECTRIC
(20)
Mitsubishi Heavy Industries
(0)
NORD
(1)
Nobu
(0)
PANASONIC
(2)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(9)
THERMOR
(3)
TOSHIBA
(16)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(1)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
CU-Z25CBEA / CS-Z25CD3EAW
2025
|
PANASONIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
AR80F09CAAWN/AR80F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AR80H09CAAWN/AR80H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AR50F09C1CHN/AR50F09C1CHX
RAC
|
SAMSUNG | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
CU-Z25UBEA / CS-Z25UD3EAW
2017
|
PANASONIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
RAS-10J2AVSG-E1/RAS-B10J2FVG-E
Console
|
TOSHIBA | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.70 | 3.90 | -15° | 2.50 | 2.50 | |
|
RAV-GM302ATP-E/RAV-HM301SDTY-E
DI
|
TOSHIBA | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.21 | 3.95 | -15° | 2.50 | 2.60 | |
|
RXM25R9 / FDXM25F9
RXM
|
DAIKIN | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.40 | 2.60 | |
|
AS07SHBHRA/1U07DEBFRA
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO SMART BLANC & UE MONO 2,1 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM BLANC & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM NOIR & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
Wall mounted - S
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
RAC-DJ25WHAE / RAK-DJ25RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.65 | -15° | 2.50 | 2.47 | |
|
RAC-VJ25NHAE / RAI-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.78 | |
|
SUZ-M25VA/MLZ-KP25VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
RAS-10CAVG-E/RAS-B10CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
38WHSM025A1A0TEE/40WHMW025D1A0TEE
40WHM
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
SUZ-M25VA/SLZ-M25FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SLZ-M25FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
AB25S2SC2FA/1U25S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.47 | 3.71 | -10° | 2.50 | 2.80 | |
|
AOEH09KNCA/ASEH09KNCA
ASE**K
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOHH09KNCA/ASHH09KNCA
ASH**K
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOYH09KNCA/ASYH09KNCA
ASY**K
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
ROH09KNCA/RSH09KNCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOHH09KNCA/ASHH09KNCH
ASH**K
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOYH09KNCA/ASYH09KNCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
MUZ-AY15VG/MSZ-AY15VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
MUZ-AY15VG2/MSZ-AY15VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
RAC-25NPE / RAD-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
RAC-25NPE / RAI-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
MOX101-07HFN8-QRD1GW/MSCB1BU-07HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.10 | 3.78 | -10° | 2.10 | 1.80 | |
|
MOM-07NXD0/MCB1-07N8-1
Breezeless E
|
MIDEA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.10 | 3.78 | -10° | 2.10 | 1.80 | |
|
MOM-07NXD0/CB1-07HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.10 | 3.78 | -10° | 2.10 | 1.80 | |
|
RAS-07E2AVG-E/RAS-B07E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
RAS-07E2AVG-E/RAS-B07S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AF25S2SD1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
AF25S2SD1FA(D)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 |