Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(28)
ATLANTIC
(23)
AUX
(18)
BOSCH
(31)
BRYANT
(4)
Buderus
(13)
CARRIER
(42)
CIAT
(8)
COLIBRI
(3)
CONFORT AIR
(1)
Candy
(15)
DAIKIN
(135)
EQUATION
(3)
FUJI ELECTRIC
(34)
FUJITSU
(82)
Fujitsu Atlantic
(41)
GENERAL
(59)
GREE
(38)
GSS
(2)
HAIER
(206)
HEC
(5)
HEIWA
(4)
HISENSE
(178)
HITACHI
(29)
IVT
(1)
Inventor
(48)
KAYSUN
(14)
LG
(108)
MIDEA
(264)
MITSUBISHI ELECTRIC
(132)
Mitsubishi Heavy Industries
(18)
NORD
(28)
Nobu
(4)
PANASONIC
(50)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(81)
THERMOR
(38)
TOSHIBA
(81)
Viessmann
(7)
Vulcano
(6)
WESTPOINT
(10)
YORK
(9)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC052BXAPKG/AC052BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.30 | 4.60 | 3.70 | -25° | 5.00 | 3.90 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
ND35MDAHRA/1N35MEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 3.50 | 3.60 | |
|
RAV-GM562ATP-E/RAV-HM561UTP-E
DI
|
TOSHIBA | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.62 | 3.90 | -15° | 5.00 | 2.80 | |
|
RAS-13P2AVSG-E/RAS-B13N4KVRG-E1
HAORI
|
TOSHIBA | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RAS-13P2AVSG-E/RAS-B13P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
RAS-13P2AVSG-E/RAS-B13P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 5.10 | 3.89 | -20° | 3.50 | 3.20 | |
|
CU-Z35CBEA / CS-Z35CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.60 | 3.98 | -15° | 3.50 | 3.20 | |
|
RXM50A9 / FTXM50A
RXM
|
DAIKIN | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.80 | 3.95 | -20° | 5.00 | 4.50 | |
|
RXM50A9 / FTXM50A
RXM
|
DAIKIN | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.80 | 3.95 | -20° | 5.00 | 4.50 | |
|
RAV-GP561ATW-E/RAV-HM561MUTP-E
SDI
|
TOSHIBA | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.27 | 4.32 | 3.50 | -27° | 5.00 | 3.80 | |
|
AUW52U4RS7/ADT52UX4RGM8
Super Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.40 | 3.82 | -10° | 5.00 | 4.00 | |
|
AUW35U4RS8/ADT35UX4RBL8
Turbo Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 4.00 | -10° | 3.50 | 3.00 | |
|
RXM50R / FTXM50R
RXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.41 | 4.71 | 4.00 | -20° | 5.00 | 4.60 | |
|
NF35DBAHRA/1N35MEAFRA
NORD - Console
|
NORD | Console | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
RXM50A8 / FTXM50A
RXM
|
DAIKIN | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.55 | 4.75 | 4.00 | -20° | 5.00 | 4.50 | |
|
AOEG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KBTB/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | 3.80 | -15° | 3.50 | 3.40 | |
|
RAC-35FXE / RAF-35RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.90 | -20° | 3.50 | 3.53 | |
|
AUW52U4RS7/ADT52UX4RCL8
Super Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.79 | -10° | 5.00 | 4.00 | |
|
MUZ-FT35VGHZ/MSZ-FT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
MUZ-FT35VGHZ2/MSZ-FT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
ARXM50R / ATXM50R
ARXM
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.65 | 3.79 | -20° | 5.00 | 4.60 | |
|
AC035BXAPKG/AC035BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | 3.81 | -25° | 3.50 | 2.30 | |
|
ARXM50A8 / ATXM50A
ARXM
|
DAIKIN | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.70 | 3.90 | -20° | 5.00 | 4.50 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
MUZ-AY42VG/MSZ-AY42VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY42VG2/MSZ-AY42VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
PUZ-ZM50VKA2/PLA-M50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PLA-M50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
SUZ-M35VA/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
SRC35ZS-W2/FDTC35VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.60 | 3.70 | -10° | 3.50 | 2.90 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
MUZ-AY35VG/MSZ-AY35VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
MUZ-AY35VG2/MSZ-AY35VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
MUZ-AY50VG/MSZ-AY50VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY50VG2/MSZ-AY50VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
2AMXM50M9 / ATXM25R / ATXM25R
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
2AMXM50M9 / ATXM25A / ATXM25A
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
U-50PZ3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.94 | -15° | 4.70 | 4.00 |