Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(3)
AUX
(0)
BOSCH
(0)
BRYANT
(1)
Buderus
(0)
CARRIER
(3)
CIAT
(1)
COLIBRI
(1)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(1)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(59)
HEC
(0)
HEIWA
(0)
HISENSE
(3)
HITACHI
(9)
IVT
(0)
Inventor
(4)
KAYSUN
(1)
LG
(2)
MIDEA
(15)
MITSUBISHI ELECTRIC
(6)
Mitsubishi Heavy Industries
(0)
NORD
(10)
Nobu
(0)
PANASONIC
(1)
PITSOS
(0)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(5)
TOSHIBA
(11)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AD300S2SH1FA(H)/1U300S2SA3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 2.55 | 28.50 | 21.00 | ||
|
AUV140UR4RC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.30 | 2.90 | -10° | 13.50 | 9.00 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
YUKF55BYOEBMO-1/YFKF55BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -15° | 15.50 | 11.90 | |
|
ND125MGAHRA/1N125TEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 2.95 | 12.50 | 9.60 | ||
|
RAS-18P2AVSG-E/RAS-B18J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 3.00 | -20° | 5.00 | 4.00 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MO-55N8-R/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
KUE-160 DTR13/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)-GR/MUE-55HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
AUC140UR4RKC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.07 | 4.40 | 2.94 | -10° | 13.50 | 9.00 | |
|
AP140S2SK1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 4.00 | 2.76 | 13.40 | 8.50 | ||
|
AP140S2SE1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 4.00 | 2.76 | 13.40 | 8.50 | ||
|
CU-Z60UBEA / CS-Z60UB4EAW
2017
|
PANASONIC | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 2.92 | -15° | 6.00 | 4.00 | |
|
AP140S2SK1FA(H)/1U140S2SN2FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 2.75 | 13.40 | 8.50 | ||
|
ND140MGAHRA/1N140TEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 2.95 | 13.00 | 9.60 | ||
|
AP140S2SE1FA(H)/1U140S2SN2FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 2.75 | 13.40 | 8.50 | ||
|
MOX630U-55HFN8-RRD0W(GA)/MFFN-55HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.00 | -10° | 15.80 | 12.20 | |
|
AP140S2SK1FA/1U140S2SN1FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 3.95 | 2.76 | 13.40 | 8.50 | ||
|
AP140S2SK1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 3.95 | 2.76 | 13.40 | 8.50 | ||
|
RPIH-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.92 | 3.00 | -15° | 10.10 | 8.20 | |
|
AP140S2SE1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 3.95 | 2.76 | 13.40 | 8.50 | ||
|
PUZ-ZM125VDA/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.40 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.40 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
NB125CFAHRA/1N125TEAFRA-W
NORD - Cassette
|
NORD | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 2.95 | 12.50 | 9.60 | ||
|
UUD1 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUD3 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
AP140S2SK1FA/1U140S2SN1FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.93 | 2.75 | 13.40 | 8.50 | ||
|
AP140S2SK1FA(H)/1U140S2SN1FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.93 | 2.75 | 13.40 | 8.50 | ||
|
RAS-4HVRC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.45 | 3.80 | 2.82 | -20° | 10.00 | 7.40 | |
|
AP140S2SE1FA(H)/1U140S2SN1FA
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.93 | 2.75 | 13.40 | 8.50 | ||
|
AB140S2SR1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 4.00 | 2.63 | 13.40 | 8.50 | ||
|
AUC175UR4RKC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 2.97 | -10° | 16.00 | 10.00 | |
|
RAS-4HVNC2E / RPK-4.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.17 | 3.83 | 2.87 | -20° | 10.00 | 7.40 | |
|
AS35PBUHRA/1U35YEUFRA
Pearl Neo
|
HAIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 2.74 | -10° | 3.50 | 3.00 | |
|
AS35PBUHRA-MT/1U35YEUFRA-MT
Pearl Plus
|
HAIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 2.74 | -10° | 3.50 | 3.00 | |
|
AS35QAIN/US35QAOD
NORD - P plus
|
NORD | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 2.74 | -10° | 3.50 | 3.00 | |
|
RAV-GV801ATP-E/RAV-HM801BTP-E
DIC
|
TOSHIBA | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 4.00 | 3.00 | -15° | 6.70 | 4.80 | |
|
RAV-GM801ATP-E/RAV-HM801KRTP-E
DI
|
TOSHIBA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.73 | 4.01 | 2.95 | -15° | 6.70 | 5.10 | |
|
AC140S2SK1FA/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK1FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
AC140S2SK2FA(H)/1U140S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.97 | 2.95 | 13.40 | 8.50 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.65 | 2.71 | -10° | 20.00 | 11.40 |