Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(7)
ATLANTIC
(8)
AUX
(41)
BOSCH
(10)
BRYANT
(3)
Buderus
(3)
CARRIER
(27)
CIAT
(7)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(27)
DE DIETRICH
(5)
EQUATION
(0)
FUJI ELECTRIC
(6)
FUJITSU
(24)
Fujitsu Atlantic
(12)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(157)
HEC
(2)
HEIWA
(0)
HISENSE
(7)
HITACHI
(28)
IVT
(0)
Inventor
(34)
KAYSUN
(13)
LG
(38)
MIDEA
(154)
MITSUBISHI ELECTRIC
(61)
Mitsubishi Heavy Industries
(35)
NORD
(24)
Nobu
(6)
PANASONIC
(4)
PITSOS
(3)
RIELLO
(9)
Rotenso
(3)
SAMSUNG
(40)
THERMOR
(8)
TOSHIBA
(64)
Viessmann
(2)
Vulcano
(4)
WESTPOINT
(2)
XTRON
(4)
YORK
(10)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
AD300S2SH1FA(H)/1U300S2SA3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 2.55 | 28.50 | 21.00 | ||
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
RAV-GM1602ATW-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.39 | -15° | 14.00 | 8.00 | |
|
AUD140UX4REH8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.07 | 4.27 | 3.18 | -10° | 13.50 | 9.00 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFFN-48HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.34 | -10° | 14.10 | 11.50 | |
|
FDC200VSA/SRK100ZR-W/SRK100ZR-W
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.67 | 3.02 | 19.00 | 12.50 | ||
|
PUZ-M140VKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
RAV-GM1602ATW-E/RAV-HM1601CTP-E
DI
|
TOSHIBA | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.30 | 3.37 | -15° | 14.00 | 8.00 | |
|
SRC71ZTL-W/SRK71ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.38 | -10° | 7.10 | 6.20 | |
|
RAV-GM1602AT8W-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.38 | 3.44 | -15° | 14.00 | 8.00 | |
|
AUV140UR4RC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.30 | 2.90 | -10° | 13.50 | 9.00 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
FDC125VNA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
ND105MFAHRA/1N105XEAFRA
NORD - MSP Duct
|
NORD | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.20 | -10° | 9.50 | 7.80 | |
|
ND105MFAHRA/1N105XEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 3.20 | -10° | 9.50 | 7.80 | |
|
YUKF55BYOEBMO-1/YFKF55BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -15° | 15.50 | 11.90 | |
|
ND125MGAHRA/1N125TEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.10 | 2.95 | 12.50 | 9.60 | ||
|
RAS-18P2AVSG-E/RAS-B18J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 3.00 | -20° | 5.00 | 4.00 | |
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 14.10 | 11.30 | |
|
AP105S2SK1FA(H)/1U105S2SQ1FA
Cabinet-Monosplit
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SQ1FA
Cabinet-Monosplit
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS2FA
Cabinet-Monosplit
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
FDC250VSA-W/FDF125VH/FDF125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDF125VH1/FDF125VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
PUZ-M140YKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140YKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
RAV-GM1602AT8W-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.22 | 3.41 | -15° | 14.00 | 8.00 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
RAV-GM562ATP-E/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.11 | 3.27 | -15° | 5.00 | 2.80 | |
|
RAS-24E2AVG-E/RAS-B24S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
RAS-24E2AVG-E/RAS-B24E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 | |
|
RAS-24CAVG-E/RAS-B24CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.33 | -15° | 6.50 | 5.40 |