Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(12)
AUX
(30)
BOSCH
(18)
BRYANT
(3)
Buderus
(6)
CARRIER
(25)
CIAT
(11)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(5)
DAIKIN
(51)
DE DIETRICH
(7)
EQUATION
(0)
FUJI ELECTRIC
(16)
FUJITSU
(46)
Fujitsu Atlantic
(23)
GENERAL
(21)
GREE
(7)
GSS
(0)
HAIER
(195)
HEC
(2)
HEIWA
(1)
HISENSE
(34)
HITACHI
(28)
IVT
(0)
Inventor
(37)
KAYSUN
(16)
LG
(35)
MIDEA
(190)
MITSUBISHI ELECTRIC
(77)
Mitsubishi Heavy Industries
(37)
NORD
(16)
Nobu
(5)
PANASONIC
(2)
PITSOS
(3)
RIELLO
(11)
Rotenso
(4)
SAMSUNG
(43)
THERMOR
(12)
TOSHIBA
(48)
Viessmann
(3)
Vulcano
(6)
WESTPOINT
(2)
XTRON
(4)
YORK
(11)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AD300S2SH1FA(H)/1U300S2SA3FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 2.55 | 28.50 | 21.00 | ||
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFFN-48HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.34 | -10° | 14.10 | 11.50 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
YUKF55BYOEBMO-1/YFKF55BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -15° | 15.50 | 11.90 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 14.10 | 11.30 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
GWHD(36)NK6OO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
GWHD(36)NK6RO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
MOX630U-48HFN8-QRD0W(GA)/MUE-48HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-48NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-42NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-Q(H)/MUE-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-QRD0W(GA)/MTJ-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MO-48N8-Q-1/MTJ-48NX
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
KUE-140 DVR14/KPD-140 DR15
Zen
|
KAYSUN | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-QRD0W(GA)-GR/MTJ-48HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
42QSV048D8S/38QUS048D8TX
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
42QSV048D8S/38QUS048D8S
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-Q(H)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MO-55N8-R/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
KUE-160 DTR13/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)-GR/MUE-55HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
AP140S2SK1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 4.00 | 2.76 | 13.40 | 8.50 | ||
|
42HY48VDS8C/38HU48VDT8C
Ducted
|
CIAT | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
42QSS048D8S*/38QUS048D8T*
Ducted
|
CARRIER | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
DC213HIDS8/AIC213HIDT8
Ducted
|
RIELLO | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
AC140RXADNG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.44 | -20° | 13.40 | 8.40 | |
|
AC140RXADKG / AC140RNMDKG
CAC
|
SAMSUNG | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.00 | 3.34 | -20° | 13.40 | 8.40 | |
|
PUZ-M100YKA2/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100VKA2/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100VKA3/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
PUZ-M100YKA3/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.00 | 3.45 | -15° | 9.40 | 8.00 | |
|
AP140S2SE1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cabinet
|
HAIER | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.66 | 4.00 | 2.76 | 13.40 | 8.50 | ||
|
AC071RXADKG/AC071RNMDKG
CAC
|
SAMSUNG | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -20° | 6.80 | 3.70 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
MOX630U-48HFN8-RRD0W(GA)/MTJ-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-R(GA)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MO-48N8-R-1/MTJ-48NX
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-RRD0W/MTJ-48HWFNX
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
KUE-140 DTR14/KPD-140 DR15
Zen
|
KAYSUN | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
N140Xi R15/UO140Xo R15
Nevo
|
Rotenso | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-R(H)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 |