Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(1)
BOSCH
(3)
BRYANT
(0)
Buderus
(2)
CARRIER
(1)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(11)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(1)
GSS
(0)
HAIER
(11)
HEC
(0)
HEIWA
(0)
HISENSE
(3)
HITACHI
(0)
IVT
(1)
Inventor
(0)
KAYSUN
(0)
LG
(8)
MIDEA
(7)
MITSUBISHI ELECTRIC
(40)
Mitsubishi Heavy Industries
(24)
NORD
(2)
Nobu
(0)
PANASONIC
(4)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(4)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.80 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.94 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.60 | 2.90 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
FDC125VNX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.94 | 4.67 | 3.00 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.79 | 3.00 | 12.50 | 14.00 | ||
|
PUZ-ZM140VDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
U-125PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.12 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
U-125PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
FDC125VSX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.94 | 4.36 | 2.91 | 12.50 | 14.00 | ||
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
FDC125VNX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.44 | 3.03 | 12.50 | 11.40 | ||
|
PUZ-ZM100VDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
RZAG60A / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -20° | 6.00 | 4.60 | |
|
AUC140UR4RKC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUC140UR4RKC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
FDC125VSX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.26 | 2.79 | 12.50 | 14.00 | ||
|
RAV-GP1101AT8-E/RAV-HM1101KRTP-E
SDI 3ph
|
TOSHIBA | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.22 | 3.45 | -20° | 10.00 | 10.80 | |
|
FDC140VSX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.14 | 2.56 | 14.00 | 15.50 | ||
|
FDC125VNX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.20 | 2.90 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 2.70 | 12.50 | 11.40 | ||
|
PUZ-ZM100YDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
FDC140VNX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.35 | 2.91 | 14.00 | 13.00 | ||
|
MFZ-KW60VG/MUFZ-KW60VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MUFZ-KW60VGHZ2/MFZ-KW60VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
UUB1 U20 / UV18F N10
UU
|
LG | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.29 | -10° | 5.00 | 4.20 | |
|
RZAG60B / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -10° | 6.00 | 4.60 | |
|
UUB1 U20 / CM18F N10
UU
|
LG | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.30 | -10° | 5.00 | 4.10 | |
|
UUB1 U20 / CM18F N11
UU
|
LG | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.30 | -10° | 5.00 | 4.10 | |
|
FDC125VNX-W/FDUM125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.06 | 2.90 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDU125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.06 | 2.90 | 12.50 | 11.40 | ||
|
AS35SBBHRA-MW/1U35DEBFRA-S
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-S
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MWV/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MW/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35PBBHRA-PA/1U35DEBFRA-S
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35RBBHRA-RBS/1U35DEBFRA-S
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SAT1-W/US35SAT1
NORD - S
|
NORD | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-S/1U35DEBFRA-S
Wall mounted - S
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
PUZ-ZM140VDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.67 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.67 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
SUZ-M50VA/MLZ-KP50VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 |