Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(5)
BRYANT
(2)
Buderus
(4)
CARRIER
(9)
CIAT
(2)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(3)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(3)
GSS
(0)
HAIER
(13)
HEC
(0)
HEIWA
(0)
HISENSE
(3)
HITACHI
(1)
IVT
(1)
Inventor
(9)
KAYSUN
(1)
LG
(6)
MIDEA
(78)
MITSUBISHI ELECTRIC
(12)
Mitsubishi Heavy Industries
(19)
NORD
(3)
Nobu
(1)
PANASONIC
(3)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(16)
THERMOR
(1)
TOSHIBA
(3)
Viessmann
(2)
Vulcano
(1)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.80 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.94 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.60 | 2.90 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
FDC125VNX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.94 | 4.67 | 3.00 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.79 | 3.00 | 12.50 | 14.00 | ||
|
FDC140VNA-W/FDF71VH/FDF71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF71VH/FDF71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDF71VH1/FDF71VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF71VH1/FDF71VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
PUZ-ZM140VDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
U-125PZH4E5 / S-1014PF3E
2023
|
PANASONIC | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.12 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
U-125PZH4E8 / S-1014PF3E
2023
|
PANASONIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.20 | 3.46 | -20° | 12.10 | 9.30 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
FDC125VSX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.94 | 4.36 | 2.91 | 12.50 | 14.00 | ||
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
FDC125VNX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.44 | 3.03 | 12.50 | 11.40 | ||
|
RAS-22P2AVSG-E/RAS-B22P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
RAS-22P2AVSG-E/RAS-B22P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
AUC140UR4RKC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUC140UR4RKC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
FDC125VSX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.26 | 2.79 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.14 | 2.56 | 14.00 | 15.50 | ||
|
UUC1 U40 / UT30F NB0
U4
|
LG | Cassette | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.40 | -10° | 8.00 | 5.60 | |
|
FDC125VNX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 2.70 | 12.50 | 11.40 | ||
|
FDC140VNX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.35 | 2.91 | 14.00 | 13.00 | ||
|
PUZ-M250YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.07 | 4.34 | 3.50 | -20° | 22.00 | 17.00 | |
|
SRC71ZTL-W/SRK71ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.38 | -10° | 7.10 | 6.20 | |
|
AS35SBBHRA-MW/1U35DEBFRA-S
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-S
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MWV/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MW/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35PBBHRA-PA/1U35DEBFRA-S
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35RBBHRA-RBS/1U35DEBFRA-S
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SAT1-W/US35SAT1
NORD - S
|
NORD | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-S/1U35DEBFRA-S
Wall mounted - S
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
MUZ-SF42VE/MSZ-SF42VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.40 | 3.42 | -15° | 4.20 | 3.80 | |
|
MUZ-SF42VEH/MSZ-SF42VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.30 | 3.42 | -20° | 4.20 | 3.80 | |
|
AOHG18KLTA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
ROG18KLTA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOHG18KLCA/ASHG18KLCA
ASH**K
|
GENERAL | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
AOYG18KLCA/ASYG18KLCA
ASY**K
|
FUJITSU | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 | |
|
ROG18KLCA/RSG18KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.50 | -15° | 5.20 | 4.80 |