Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(0)
BOSCH
(3)
BRYANT
(0)
Buderus
(0)
CARRIER
(5)
CIAT
(3)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(16)
EQUATION
(0)
FUJI ELECTRIC
(5)
FUJITSU
(10)
Fujitsu Atlantic
(5)
GENERAL
(5)
GREE
(0)
GSS
(0)
HAIER
(50)
HEC
(0)
HEIWA
(0)
HISENSE
(8)
HITACHI
(8)
IVT
(0)
Inventor
(5)
KAYSUN
(10)
LG
(25)
MIDEA
(63)
MITSUBISHI ELECTRIC
(48)
Mitsubishi Heavy Industries
(22)
NORD
(4)
Nobu
(0)
PANASONIC
(5)
RIELLO
(3)
Rotenso
(3)
SAMSUNG
(16)
THERMOR
(1)
TOSHIBA
(12)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
YORK
(5)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
AUV140UR4RC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
AUV140UR4RC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
PUZ-ZM140VDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
AC140BXAPNG / AC140BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.40 | 3.41 | -25° | 13.40 | 9.20 | |
|
FDC125VNX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.44 | 3.03 | 12.50 | 11.40 | ||
|
PUZ-M200YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.20 | 3.30 | -20° | 19.00 | 15.50 | |
|
AC100RXADKG/AC100RN4PKG
CAC
|
SAMSUNG | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.50 | -20° | 10.00 | 5.30 | |
|
AUC140UR4RKC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUC140UR4RKC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
FDC125VSX-W/FDT125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.64 | 4.26 | 2.79 | 12.50 | 14.00 | ||
|
FDC140VSX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.14 | 2.56 | 14.00 | 15.50 | ||
|
UUC1 U40 / UT30F NB0
U4
|
LG | Cassette | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.40 | -10° | 8.00 | 5.60 | |
|
FDC125VNX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 2.70 | 12.50 | 11.40 | ||
|
UUD1 U30 / UT60FH NA0
UU
|
LG | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.50 | 3.25 | 15.00 | 9.50 | ||
|
UUD3 U30 / UT60FH NA0
UU
|
LG | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.50 | 3.25 | 15.00 | 9.50 | ||
|
FDC140VNX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.35 | 2.91 | 14.00 | 13.00 | ||
|
RAV-GM1602ATW-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.39 | -15° | 14.00 | 8.00 | |
|
U-60PZH3E5 / S-60PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.40 | -20° | 6.00 | 4.60 | |
|
PUZ-M250YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.07 | 4.34 | 3.50 | -20° | 22.00 | 17.00 | |
|
PUZ-M140VKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
RZAG140NV1 / FCAG140B
RZAG
|
DAIKIN | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.34 | 3.41 | 13.40 | 9.52 | ||
|
RAV-GM1602AT8W-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.38 | 3.44 | -15° | 14.00 | 8.00 | |
|
AUV140UR4RC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.30 | 2.90 | -10° | 13.50 | 9.00 | |
|
FDC125VNA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDTC60VH/FDTC60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.36 | 3.26 | 12.50 | 9.80 | ||
|
YUKF55BYOEBMO-1/YFKF55BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling/Floor | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -15° | 15.50 | 11.90 | |
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
RZAG60A / FCAG60B
RZAG
|
DAIKIN | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.25 | 3.40 | -20° | 6.00 | 4.60 | |
|
PUZ-ZM140VDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.67 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.67 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
AC140RXADKG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.16 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4DKG
CAC
|
SAMSUNG | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 3.25 | -20° | 13.40 | 8.40 | |
|
SUZ-M50VA/MLZ-KP50VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 | |
|
PUZ-ZM140YDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.28 | 4.11 | 3.50 | -10° | 20.00 | 11.40 |