Filters · 5 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(10)
ATLANTIC
(4)
AUX
(8)
BOSCH
(3)
BRYANT
(0)
Buderus
(1)
CARRIER
(11)
CIAT
(7)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(23)
EQUATION
(0)
FUJI ELECTRIC
(17)
FUJITSU
(54)
Fujitsu Atlantic
(19)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(81)
HEC
(0)
HEIWA
(0)
HISENSE
(18)
HITACHI
(13)
IVT
(0)
Inventor
(10)
KAYSUN
(2)
LG
(19)
MIDEA
(11)
MITSUBISHI ELECTRIC
(37)
Mitsubishi Heavy Industries
(48)
NORD
(2)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(10)
THERMOR
(3)
TOSHIBA
(22)
Viessmann
(5)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-71PZH4E5 / S-6071PT3E
2023
|
PANASONIC | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.70 | 3.96 | -20° | 6.80 | 4.70 | |
|
AUV125UR4RC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
AUV125UR4RC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
U-71PZH4E8 / S-6071PT3E
2023
|
PANASONIC | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.70 | 3.96 | -20° | 6.80 | 4.70 | |
|
RAV-GP1401AT-E1/RAV-HM1401CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.99 | 4.73 | 3.90 | -27° | 12.50 | 9.60 | |
|
FDC125VNX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.94 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.79 | 3.00 | 12.50 | 14.00 | ||
|
U-100PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
AC071BXAPKG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC071BXAPNG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
U-100PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
AUV140UR4RC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
AUV140UR4RC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
CU-Z35CBEA / CS-Z35CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.60 | 3.98 | -15° | 3.50 | 3.20 | |
|
FDC125VNA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VNA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
RAV-GM802ATW-E/RAV-HM801CTP-E
DI
|
TOSHIBA | Ceiling suspended | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.48 | 3.87 | -15° | 6.90 | 5.10 | |
|
NF35DBAHRA/1N35MEAFRA
NORD - Console
|
NORD | Console | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.60 | |
|
SRC60ZSX-W3/FDE60VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.72 | 4.41 | 3.60 | -20° | 5.60 | 4.50 | |
|
UUC1 U40 / UV30FH N20
U4
|
LG | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -10° | 8.00 | 5.40 | |
|
RAV-GM902ATW-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.03 | 4.60 | 4.00 | -15° | 8.00 | 6.30 | |
|
U-125PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.04 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
U-125PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
PUZ-ZM125VDA/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.39 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
RAV-GM1102ATW-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.91 | -15° | 9.50 | 8.00 | |
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
PUZ-ZM140VDA/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM125YDA/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.34 | 3.30 | -20° | 12.50 | 9.30 | |
|
RZAG100NV1 / FHA100A
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.61 | 3.97 | -10° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PCA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PCA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.30 | 3.60 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM140YDA/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.31 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.31 | 4.44 | 3.40 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.66 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
RZAG50A / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.71 | -20° | 5.00 | 4.00 | |
|
U-140PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.64 | 4.31 | 3.38 | -20° | 13.40 | 10.20 | |
|
UUC1 U40 / UV30F N10
U4
|
LG | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 3.44 | -10° | 7.70 | 5.40 | |
|
AUW105U4RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 | |
|
AUW105U6RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 |