Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(70)
ATLANTIC
(38)
AUX
(134)
BOSCH
(81)
BRYANT
(6)
Buderus
(28)
CARRIER
(116)
CIAT
(35)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(16)
DAIKIN
(305)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(113)
FUJITSU
(293)
Fujitsu Atlantic
(143)
GENERAL
(155)
GREE
(81)
GSS
(4)
HAIER
(520)
HEC
(5)
HEIWA
(6)
HISENSE
(324)
HITACHI
(118)
IVT
(3)
Inventor
(135)
KAYSUN
(65)
LG
(271)
MIDEA
(719)
MITSUBISHI ELECTRIC
(463)
Mitsubishi Heavy Industries
(266)
NORD
(51)
Nobu
(8)
PANASONIC
(155)
PITSOS
(6)
RIELLO
(38)
Rotenso
(8)
SAMSUNG
(160)
THERMOR
(56)
TOSHIBA
(216)
Viessmann
(22)
Vulcano
(16)
WESTPOINT
(20)
XTRON
(4)
YORK
(35)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-AY42VG/MSZ-AY42VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
MUZ-AY42VG2/MSZ-AY42VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.70 | 3.74 | -20° | 4.20 | 3.80 | |
|
U-125PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.04 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
AUW105U4RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
ASW-H24F4A4/CAR3DI-C8 / ASW-H24F4A4/CAR3DI-C8
C SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.08 | -10° | 6.10 | 5.40 | |
|
ASW-H24F4A4/MAR3DI-C8 / ASW-H24F4A4/MAR3DI-C8
M SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.04 | -10° | 6.10 | 5.40 | |
|
MOST 70 (7906267) / UMT 2 70 (7906265)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.04 | -10° | 6.10 | 5.40 | |
|
RTX71MCU1-T1A/FTXM71CU1-A
C SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.08 | -10° | 6.10 | 5.40 | |
|
ASW-H24F1A4/CMR3DI-C8 / ASW-H24F1A4/CMR3DI-C8
C SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.08 | -10° | 6.10 | 5.40 | |
|
PUZ-ZM140YDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
U-125PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.47 | 3.78 | -20° | 12.10 | 9.50 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
FDC140VNX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC140VSX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
RAV-GM901ATP-E/RAV-HM901UTP-E
DI
|
TOSHIBA | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -15° | 8.00 | 6.30 | |
|
MUZ-AY35VG/MSZ-AY35VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
MUZ-AY35VG2/MSZ-AY35VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
PUZ-M200YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.35 | 3.60 | -20° | 19.00 | 15.50 | |
|
PUZ-ZM50VKA2/PLA-M50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PLA-M50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 3.79 | -11° | 5.00 | 3.80 | |
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
FDC125VNA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
MUZ-AY50VG/MSZ-AY50VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY50VG2/MSZ-AY50VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
PUZ-ZM140VDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
SUZ-M35VA/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
SUZ-M71VA/PLA-M71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.50 | 3.61 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PLA-M71EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.50 | 3.61 | -10° | 7.10 | 5.80 | |
|
SRC35ZS-W2/FDTC35VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.60 | 3.70 | -10° | 3.50 | 2.90 | |
|
2AMXM50M9 / ATXM25R / ATXM25R
2AMXM
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
2AMXM50M9 / ATXM25A / ATXM25A
2AMXM
|
DAIKIN | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
PUZ-ZM140VDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
AS71PEBHRA-PA/1U71WS3FRA
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MB2/1U71WS3FRA
HAIER - FLEXIS S 24k
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MW2/1U71WS3FRA
HAIER - FLEXIS S 24k
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71REBHRA-RBS/1U71WS3FRA
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MWV/1U71WEAFRA-SH
Serene
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-S/1U71WS3FRA
Serene
|
HAIER | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
PUZ-ZM140YDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 |