Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(9)
CIAT
(5)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(46)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(12)
Fujitsu Atlantic
(4)
GENERAL
(3)
GREE
(0)
GSS
(0)
HAIER
(42)
HEC
(0)
HEIWA
(0)
HISENSE
(3)
HITACHI
(4)
IVT
(0)
Inventor
(15)
KAYSUN
(1)
LG
(5)
MIDEA
(13)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(50)
NORD
(0)
Nobu
(0)
PANASONIC
(2)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(7)
THERMOR
(0)
TOSHIBA
(18)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(3)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZASG140MV
RZASG
|
DAIKIN | Floor standing | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.71 | 4.43 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Floor standing | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.71 | 4.43 | 13.40 | 7.80 | |||
|
FDC140VSA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC140VNA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC125VNA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VNA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC140VNA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE71VH/FDE71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.06 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
AUF175UR4RHPA8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.80 | -10° | 16.00 | 10.00 | |
|
FDC200VSA-W/FDF100VH/FDF100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
FDC200VSA-W/FDF100VH1/FDF100VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.73 | 3.70 | 20.00 | 12.50 | ||
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.21 | 4.75 | 12.10 | 6.00 | |||
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
MOX630U-48HFN8-QRD0W(GA)/MFFN-48HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.34 | -10° | 14.10 | 11.50 | |
|
MOE30U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.51 | -10° | 13.70 | 10.60 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
RAV-GM1602ATW-E/RAV-HM1601CTP-E
DI
|
TOSHIBA | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.30 | 3.37 | -15° | 14.00 | 8.00 | |
|
42QZL036D8S*/38QUS036D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
42HU36VDS8C/38HU36VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
SC210HIDS8/AIC210HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100MFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.52 | 4.71 | 12.10 | 6.00 | |||
|
42QFD048D8S*/38QUS048D8T*
Floor Standing
|
CARRIER | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.74 | 14.60 | 11.00 | ||
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
AUF140UR4RMPA8/AUW140U6RQ7
Turbo Inverter R32
|
HISENSE | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.54 | -10° | 13.50 | 8.50 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 14.10 | 11.30 | |
|
FDC250VSA-W/FDF125VH/FDF125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
FDC250VSA-W/FDF125VH1/FDF125VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.78 | 4.25 | 3.35 | 24.00 | 14.20 | ||
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
PUZ-M140YKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140YKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
RAV-GM1602AT8W-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.22 | 3.41 | -15° | 14.00 | 8.00 |