Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(12)
Fujitsu Atlantic
(9)
GENERAL
(9)
GREE
(0)
GSS
(0)
HAIER
(13)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(6)
IVT
(0)
Inventor
(1)
KAYSUN
(0)
LG
(22)
MIDEA
(0)
MITSUBISHI ELECTRIC
(38)
Mitsubishi Heavy Industries
(127)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-FH35VEHZ/MSZ-FH35VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.90 | 4.80 | 5.00 | -25° | 3.50 | 4.00 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
MUZ-FH35VE/MSZ-FH35VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.90 | 5.10 | 5.00 | -15° | 3.50 | 3.60 | |
|
FDC140VSA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC140VNA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC125VNA/FDT60VH/FDT60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.97 | 5.21 | 4.23 | 12.50 | 9.80 | ||
|
FDC125VSA/FDT60VH/FDT60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.97 | 5.21 | 4.23 | 12.50 | 9.80 | ||
|
FDC140VNA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC125VNA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC200VSA/FDUM100VH/FDUM100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.77 | 3.71 | 19.00 | 12.50 | ||
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.01 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
FDC140VNA/FDT71VH/FDT71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.51 | 4.89 | 4.17 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT71VH/FDT71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.51 | 4.89 | 4.17 | 13.60 | 10.50 | ||
|
FDC140VNX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC140VSX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC125VNA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC125VSX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.18 | 3.83 | 12.50 | 14.00 | ||
|
FDC100VNA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.26 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC140VSA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
FDC100VNA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT50VH/FDT50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.89 | 4.47 | 4.11 | -20° | 10.00 | 8.50 | |
|
FDC200VSA/FDT100VH/FDT100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.37 | 4.58 | 3.72 | 19.00 | 12.50 | ||
|
FDC125VNX/FDUM60VH/FDUM60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.21 | 4.26 | 3.83 | 12.50 | 11.40 | ||
|
FDC250VSA/FDUM125VH/FDUM125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.50 | 3.59 | 24.00 | 14.20 | ||
|
FDC100VNA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDE100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.31 | 4.15 | -20° | 10.00 | 8.50 | |
|
FDC125VSX/FDT60VH/FDT60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.04 | 4.44 | 4.35 | 12.50 | 14.00 | ||
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
FDC100VNA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VNA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDU100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.11 | 4.19 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC125VNX/FDT60VH/FDT60VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.83 | 4.46 | 4.35 | 12.50 | 11.40 | ||
|
FDC125VNX/SRK60ZSX-W/SRK60ZSX-W
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.56 | 4.02 | 12.50 | 11.40 | ||
|
FDC125VSX/SRK60ZSX-W/SRK60ZSX-W
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.56 | 4.02 | 12.50 | 11.40 | ||
|
MUZ-EF42VE/MSZ-EF42VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 3.70 | -15° | 4.20 | 3.80 | |
|
MUZ-FH50VE/MSZ-FH50VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.05 | -15° | 5.00 | 4.50 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
FDC100VNA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/SRK100ZR-W
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.26 | 4.33 | 4.03 | -20° | 10.00 | 8.50 |