Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(0)
AUX
(2)
BOSCH
(3)
BRYANT
(0)
Buderus
(0)
CARRIER
(3)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(5)
EQUATION
(0)
FUJI ELECTRIC
(5)
FUJITSU
(10)
Fujitsu Atlantic
(5)
GENERAL
(5)
GREE
(1)
GSS
(0)
HAIER
(9)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(2)
IVT
(0)
Inventor
(2)
KAYSUN
(2)
LG
(5)
MIDEA
(14)
MITSUBISHI ELECTRIC
(18)
Mitsubishi Heavy Industries
(2)
NORD
(0)
Nobu
(0)
PANASONIC
(5)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(2)
TOSHIBA
(11)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-36PZ3E5/S-3650PU3E
2019
|
PANASONIC | Cassette | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.80 | 5.07 | -15° | 3.60 | 2.80 | |
|
PUZ-ZM35VKA2/PLA-ZM35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 5.00 | -11° | 3.60 | 2.50 | |
|
PUZ-ZM35VKA3/PLA-ZM35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 5.00 | -11° | 3.60 | 2.70 | |
|
SUZ-M35VA/PLA-M35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.70 | 4.20 | -10° | 3.60 | 2.60 | |
|
RAV-GM562ATP-E/RAV-HM561UTP-E
DI
|
TOSHIBA | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.84 | 4.62 | 3.90 | -15° | 5.00 | 2.80 | |
|
AC052RXADKG/AC052RN4DKG
CAC
|
SAMSUNG | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.30 | 4.03 | -20° | 5.00 | 2.60 | |
|
SUZ-M35VA2/PLA-M35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.70 | 4.20 | -10° | 3.60 | 3.00 | |
|
AC035BXAPKG/AC035BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | 3.81 | -25° | 3.50 | 2.30 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
SUZ-M35VA/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
SRC35ZS-W2/FDTC35VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.60 | 3.70 | -10° | 3.50 | 2.90 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
RZAG35A / FCAG35B
RZAG
|
DAIKIN | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.30 | -20° | 3.50 | 3.30 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
AUW26U4RS8/ACT26UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 4.27 | -10° | 2.60 | 3.00 | |
|
SUZ-M35VA/MLZ-KP35VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.71 | -10° | 3.50 | 2.60 | |
|
PUZ-ZM35VKA2/PLA-M35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.50 | |
|
AUW35U4RS8/ACT35UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 4.00 | -10° | 3.50 | 3.00 | |
|
RAV-GM402ATP-E/RAV-HM401MUTP-E
DI
|
TOSHIBA | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.46 | 4.21 | -15° | 3.60 | 2.70 | |
|
PUZ-ZM35VKA3/PLA-M35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.70 | |
|
RXM35R9 / FCAG35B
RXM
|
DAIKIN | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.35 | 4.90 | 3.77 | -15° | 3.50 | 3.32 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
U-25PZ3E5 / S-25PY3E
2022
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -15° | 2.50 | 2.80 | |
|
RAV-GM561ATP-E1/RAV-HM561UTP-E
DI
|
TOSHIBA | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.60 | 3.90 | -15° | 5.00 | 2.80 | |
|
RZAG35B / FCAG35B
RZAG
|
DAIKIN | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.30 | -10° | 3.50 | 3.30 | |
|
U-36PZ3E5 / S-36PY3E
2022
|
PANASONIC | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.29 | -15° | 3.60 | 2.80 | |
|
AOYG12KBTB/AUXG12KVLA
AUY**K
|
FUJITSU | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KBTB/AUXG12KVLA
AUH**K
|
GENERAL | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROG12KBTB/RCG12KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOEG12KBTB/AUXG12KVLA
AUXG**K
|
FUJITSU | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/AUXG12KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.80 | -15° | 3.50 | 3.40 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
RAC-VJ35NHAE / RAI-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.78 | |
|
RAV-GM302ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.13 | 4.57 | 4.47 | -15° | 2.50 | 2.30 | |
|
SUZ-M35VA2/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.71 | -10° | 3.50 | 2.70 | |
|
SUZ-M35VA/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.71 | -10° | 3.50 | 2.60 | |
|
GUD35T1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.20 | -10° | 3.50 | 3.10 | ||
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 | |
|
RAV-GM562ATP-E/RAV-HM561MUTP-E
DI
|
TOSHIBA | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.40 | 3.61 | -15° | 5.00 | 2.80 | |
|
RAV-GM301ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.31 | 4.54 | 4.47 | -15° | 2.50 | 2.30 | |
|
RAC-VJ25NHAE / RAI-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.78 | |
|
CU-Z35UBEA / CS-Z35UB4EAW
2017
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.31 | -15° | 3.50 | 3.00 | |
|
RAV-GM401ATP-E/RAV-HM401MUTP-E
DI
|
TOSHIBA | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.44 | 4.21 | -15° | 3.60 | 2.70 | |
|
SUZ-M25VA/MLZ-KP25VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 |