Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(32)
ATLANTIC
(13)
AUX
(14)
BOSCH
(28)
BRYANT
(4)
Buderus
(10)
CARRIER
(29)
CIAT
(14)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(86)
EQUATION
(4)
FUJI ELECTRIC
(21)
FUJITSU
(56)
Fujitsu Atlantic
(27)
GENERAL
(26)
GREE
(28)
GSS
(3)
HAIER
(169)
HEC
(5)
HEIWA
(3)
HISENSE
(86)
HITACHI
(9)
IVT
(0)
Inventor
(43)
KAYSUN
(11)
LG
(104)
MIDEA
(179)
MITSUBISHI ELECTRIC
(42)
Mitsubishi Heavy Industries
(4)
NORD
(13)
Nobu
(6)
PANASONIC
(10)
RIELLO
(14)
Rotenso
(0)
SAMSUNG
(39)
THERMOR
(31)
TOSHIBA
(33)
Viessmann
(4)
Vulcano
(10)
WESTPOINT
(0)
YORK
(15)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
U-50PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.00 | 3.62 | -15° | 5.00 | 3.80 | |
|
ND35LBAHRA/1N35MEAFRA
NORD - LSP Duct
|
NORD | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.71 | -10° | 3.50 | 2.60 | |
|
GUD35PS1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | -10° | 3.50 | 3.00 | ||
|
42HY18VDS8C/38HU18VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
DC250HIDS8/AIC250HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
42QSS018D8S*/38QUS018D8S*
Ducted
|
CARRIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
AC50S2SG1FA/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC50S2SG1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
MOX330U-18HFN8-QRD0W(GA)/MTIU-18HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
MOX330U-18HFN8-Q(GA)/MTIU-18HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
MOX330U-18HFN8-QRD0W(GA)/MTIU-18HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
MO-18N8-Q/MTIU-18HNX
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
KUE-52 DVR13/KPD-52 DR14
ZEN Duct
|
KAYSUN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
U7RS-18/V7DI-18WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
MOX330U-18HFN8-QRD0W(GA)-GR/MTIU-18HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
YUKF18BYEEBMO-1/YEKF18BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
AC 018 DB.UI/1U 018 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.00 | 3.71 | -10° | 5.20 | 4.40 | |
|
AOYG14KBTB/ARXG14KHTAP
ARY**K
|
FUJITSU | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOHG14KBTB/ARXG14KHTAP
ARH**K
|
GENERAL | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
ROG14KBTB/RDG14KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KHTAP
ARXG**K
|
FUJITSU | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXG14KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.00 | -15° | 4.30 | 3.80 | |
|
MOX230-12HFN8-QRD0W(GA)/MTIU-12HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-Q(GA)/MTIU-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
42HY12VDS8C/38HU12VDS8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
DC235HIDS8/AIC235HIDS8
Ducted
|
RIELLO | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
CL5000L 35 E / CL5000iU D 35 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QRD0W(GA)/MTIU-12HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MO-12N8-Q/MTIU-12HNX
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
KUE-35 DVR13/KPD-35 DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
KUE-35 DVR13/KPD-35V DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
42QSS012D8S*/38QUS012D8S*
Ducted
|
CARRIER | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7DI-12WiFiR
Ducted R32
|
Inventor | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QRD0W(GA)-GR/MTIU-12HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
YUKF12BYEEBMO-1/YEKF12BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOHG18KBTA3/ASHG07KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
GUD50PS1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | -10° | 5.30 | 3.90 | ||
|
AC071RXADKG/AC071RNMDKG
CAC
|
SAMSUNG | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -20° | 6.80 | 3.70 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
5MWXM90A9 / FBA71A9
5MWXM
|
DAIKIN | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.00 | 3.89 | -15° | 6.80 | 4.60 | |
|
AOYG12KBTB/ARXG12KLLAP
ARY**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KBTB/ARXG12KLLAP
ARH**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROG12KBTB/RDG12KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 |