Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(1)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(1)
DAIKIN
(4)
EQUATION
(2)
FUJI ELECTRIC
(1)
FUJITSU
(2)
Fujitsu Atlantic
(1)
GENERAL
(2)
GREE
(0)
GSS
(0)
HAIER
(11)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(2)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(6)
MIDEA
(0)
MITSUBISHI ELECTRIC
(14)
Mitsubishi Heavy Industries
(4)
NORD
(0)
Nobu
(0)
PANASONIC
(1)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(2)
TOSHIBA
(2)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
RAS-2.5HVRC3 / RPI-2.5FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.11 | 3.92 | 3.80 | -25° | 5.60 | 5.20 | |
|
FDC100VNX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
FDC100VSX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MUZ-AY15VG/MSZ-AY15VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
MUZ-AY15VG2/MSZ-AY15VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
UUA1 UL0 / UT09FH NQ0
UU
|
LG | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
3MXM52A9 / FDXM25F9 / FDXM25F9
3MXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FDXM25F9 / FDXM25F9
4MWXM
|
DAIKIN | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.83 | 3.69 | -15° | 5.00 | 4.80 | |
|
SRC25ZS-W2/FDTC25VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.08 | -10° | 2.50 | 2.40 | |
|
UUA1 UL0 / CT09F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
RM2U15 U18 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.09 | 4.00 | 4.38 | -10° | 4.10 | 3.60 | |
|
PUZ-ZM35VKA3/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.70 | |
|
AS25S2SF1FA-MW3/1U25MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS 009 NBB.UI/1U 009 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS25S2SF1FA-MB3/1U25MEHFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
AS25S2SF1FA-S/1U25S2SM1FA-2
Super Match mono Flexis-Silver
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
Virtus-9K-IN/Virtus-9K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
Virtus-12K-IN/Virtus-12K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 3.81 | -10° | 3.50 | 2.80 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 | |
|
RZAG35A / FFA35A9
RZAG
|
DAIKIN | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -20° | 3.50 | 4.20 | |
|
SUZ-M35VA2/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 3.00 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
SRC25ZS-W2/SRF25ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 4.39 | -10° | 2.50 | 2.40 | |
|
AOHG07KPCA/ASHG07KPCA
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOHG07KPCA/ASHG07KPCE
ASH**L
|
GENERAL | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
ROG07KPCA/RSG07KPCE
RS**K
|
FUJI ELECTRIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOYG07KPCA/ASYG07KPCE
ASY**K
|
FUJITSU | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOEG07KPCA/ASEG07KPCE
ASE**K
|
FUJITSU | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOYG07KPCA/ASYG07KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
PUZ-ZM35VKA2/PKA-M35LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PKA-M35LAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
UUA1 UL0 / MJ09PC NSJ
UU
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.50 | -10° | 2.50 | 2.80 | |
|
UUA1 UL0 / MJ09PC NSJ0
UU
|
LG | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 4.50 | -10° | 2.50 | 2.80 | |
|
SUZ-M35VA/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 2.60 | |
|
UUA1 UL0 / UQ09F NA0
UU
|
LG | Console | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.20 | -10° | 2.60 | 2.80 | |
|
RAV-GM302ATP-E/RAV-HM301KRTP-E
DI
|
TOSHIBA | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.26 | 3.98 | 4.00 | -15° | 2.50 | 2.60 | |
|
AS25S2SF1FA-MW3/AS35S2SF1FA-MW3/2U40S2SM1FA
Super Match Multi-Flexis
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
NAGANO U.I 2600W R32+NAGANO U.I 3500W R32/NAGANO U.E BI 4000W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
AS25S2SF1FA-MB3/AS35S2SF1FA-MB3/2U40S2SM1FA
Super Match Multi-Flexis Plus
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM26V2-NG + IM35V2-NG/NAGANO U.E BI 4000W R32
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
2U40S2SM1FA/AS25PBPHRA-PRE/AS35PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
H2U14MAAOUT/AS25SBBHRA-MB/AS35SBBHRA-MB
Super Match Multi
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 |