Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(4)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(8)
CIAT
(5)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(36)
EQUATION
(0)
FUJI ELECTRIC
(11)
FUJITSU
(35)
Fujitsu Atlantic
(13)
GENERAL
(7)
GREE
(0)
GSS
(0)
HAIER
(33)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(4)
IVT
(0)
Inventor
(6)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(6)
Mitsubishi Heavy Industries
(10)
NORD
(0)
Nobu
(0)
PANASONIC
(4)
RIELLO
(5)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(0)
TOSHIBA
(2)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(3)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-2HVRC3 / RPC-2.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.00 | 4.09 | -25° | 5.00 | 5.00 | |
|
FDC100VNX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
FDC100VSX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
RPIH-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.86 | -15° | 7.30 | 6.00 | |
|
AC50S2SG1FA/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC50S2SG1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC 018 DB.UI/1U 018 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.00 | 3.71 | -10° | 5.20 | 4.40 | |
|
AL-H24/4DR3HB3(U) / AUCF-H24/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
RXYL71M-T1B/FDCF71F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 7.03 | 5.50 | |
|
AL-H36/4DR3C3(U) / AUCF-H36/4DR3HC2
F-Ceiling suspended
|
AUX | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDCF105F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
42QZL036D8S*/38QUS036D8T*
Ceiling suspended
|
CARRIER | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
42HU36VDS8C/38HU36VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
SC210HIDS8/AIC210HIDT8
Ceiling suspended
|
RIELLO | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
AC71S2SG1FA/1U71S2ST1FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 4.00 | 3.52 | -10° | 7.10 | 5.00 | |
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
FDC140VSX-W/FDE140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 3.96 | 2.50 | 14.00 | 15.50 | ||
|
AOYG30KBTB/ABYG30KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ABHG30KRTA
ABH**K
|
GENERAL | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG30KBTB/RYG30KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KBTB/ABEG30KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KBTB/ABYG30KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.64 | 3.85 | 3.85 | 19.00 | 11.20 | ||
|
AL-H18/4DR3HB3(U) / AUCF-H18/4DR3HA2
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
RXYL52M-T1B/FDCF52F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.77 | -10° | 5.30 | 4.50 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.32 | 3.89 | 3.89 | 19.00 | 11.20 | ||
|
AC105S2SH1FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC 036 DB.UI/1U 036 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.23 | -10° | 9.50 | 7.00 | |
|
YUKF36BYOEBMO-1/YFKF36BXOEBM-R1
Grande Ceiling&Floor R32
|
YORK | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ABHG22KRTA
ABH**K
|
GENERAL | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
ROG22KBTB/RYG22KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ABEG22KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.59 | -15° | 6.00 | 4.80 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
SC270HIDS8/AIC270HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
AC71S2SG2FA(H)/1U71S2SR3FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
YDAM-070R-09M22/FDHM-070N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
42QZL048D8S/38QUS048D8S
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
AUW105U4RK7/AUV105UR4RC8
Super Inverter R32
|
HISENSE | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -10° | 9.50 | 8.00 | |
|
42HU48VDS8C/38HU48VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 |