Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(21)
ATLANTIC
(11)
AUX
(14)
BOSCH
(22)
BRYANT
(4)
Buderus
(11)
CARRIER
(22)
CIAT
(8)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(54)
EQUATION
(4)
FUJI ELECTRIC
(6)
FUJITSU
(11)
Fujitsu Atlantic
(6)
GENERAL
(8)
GREE
(32)
GSS
(4)
HAIER
(181)
HEC
(5)
HEIWA
(3)
HISENSE
(117)
HITACHI
(13)
IVT
(0)
Inventor
(42)
KAYSUN
(4)
LG
(93)
MIDEA
(157)
MITSUBISHI ELECTRIC
(38)
Mitsubishi Heavy Industries
(0)
NORD
(16)
Nobu
(6)
PANASONIC
(33)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(36)
THERMOR
(31)
TOSHIBA
(26)
Viessmann
(2)
Vulcano
(14)
WESTPOINT
(0)
YORK
(11)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-200PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 3.94 | 3.80 | -20° | 19.00 | 15.70 | |
|
GWHD(36)NK6OO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
GWHD(36)NK6RO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
GWHD(42)NK6QO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
GWHD(42)NK6ZO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
U-250PZH4E8 + P‐VTVF250MC5‐PE
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-250PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.48 | 3.90 | 3.80 | -20° | 22.00 | 16.70 | |
|
AOHG24KLTA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLTA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
ROG24KLCA/RSG24KLCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOHG24KLCA/ASHG24KLCA
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOEG24KLCA/ASEG24KLCA
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOHG18KBTA3/ASHG07KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
ROG18KBTA3/RSG07KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOEG18KBCA3/ASEH07KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AOYG18KBTA3/ASYG07KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.98 | -15° | 5.40 | 5.00 | |
|
AS71PEPHRA-PRE/1U71WEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.00 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71PEPHRA-PRE/1U71WEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.00 | 3.80 | -10° | 7.10 | 5.60 | |
|
MUZ-AY15VG/MSZ-AY15VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
MUZ-AY15VG2/MSZ-AY15VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
CU-5Z90CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 4.43 | -15° | 9.00 | 8.50 | |
|
4U105S2LS1FA/AS50PDPHRA-PRE+AS50PDPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 10.50 | 7.50 | |
|
GWHD(21)NK6OO GWH09AGCXB-K6DNA1G/I+GWH12AGCXD-K6DNA1D/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.00 | 3.60 | -10° | 6.10 | 6.10 | |
|
RZA200D
RZA
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.91 | 3.85 | 19.00 | 11.20 | |||
|
MXZ-4F83VFHZ2/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.14 | 4.00 | 3.28 | -25° | 8.30 | 9.00 | |
|
MXZ-4F83VFHZ3/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.14 | 4.00 | 3.28 | -25° | 8.30 | 9.00 | |
|
U-200PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.41 | 3.89 | 3.71 | -20° | 17.50 | 15.70 | |
|
MXZ-4F80VF4/MSZ-AY42VG/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 3.93 | 3.31 | -15° | 6.80 | 7.00 | |
|
MXZ-4F80VF5/MSZ-AY42VGK(P)2/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 3.93 | 3.31 | -15° | 6.80 | 7.00 | |
|
RZA200D
RZA
|
DAIKIN | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.96 | 3.82 | 19.00 | 11.20 | |||
|
U-100PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
U-100PZ3E5 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
U-100PZ3E8 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
U-125PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
U-125PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
FUJITSU | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOHG24KBTA3/ASHG12KMCC/ASHG12KMCC
AOH**K Multi
|
GENERAL | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
ROG24KBTA3/RSG12KMCC/RSG12KMCC
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOEG24KBCA3/ASEH12KMCG/ASEH12KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
AOYG24KBTA3/ASYG12KMCC/ASYG12KMCC
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.83 | -15° | 6.80 | 5.80 | |
|
U-100PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
U-100PZ3E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 |