Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(43)
ATLANTIC
(19)
AUX
(42)
BOSCH
(42)
BRYANT
(4)
Buderus
(14)
CARRIER
(59)
CIAT
(32)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(239)
EQUATION
(4)
FUJI ELECTRIC
(68)
FUJITSU
(173)
Fujitsu Atlantic
(85)
GENERAL
(81)
GREE
(35)
GSS
(4)
HAIER
(349)
HEC
(5)
HEIWA
(3)
HISENSE
(126)
HITACHI
(43)
IVT
(0)
Inventor
(78)
KAYSUN
(46)
LG
(156)
MIDEA
(361)
MITSUBISHI ELECTRIC
(148)
Mitsubishi Heavy Industries
(87)
NORD
(19)
Nobu
(6)
PANASONIC
(60)
RIELLO
(32)
Rotenso
(8)
SAMSUNG
(66)
THERMOR
(41)
TOSHIBA
(74)
Viessmann
(8)
Vulcano
(14)
WESTPOINT
(0)
YORK
(32)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX630U-55HFN8-RRD0W(GA)-GR/MTJ-55HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
N160Xi R15/UO160Xo R15
Nevo
|
Rotenso | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
42QSV060D8S/38QUS060D8TX
Duct R32
|
CARRIER | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R(H)/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
MOX630U-55HFN8-R OUT V1/MTJ-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-Q(GA)/MTI-30HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MO-30N8-Q/MTI-30HNX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
KUE-90 DVR13/KPD-90 DR14
ZEN Duct
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
YUKF30BYEEBMO-1/YEKF30BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
FDC100VNX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
FDC100VSX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
GWHD(36)NK6OO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
GWHD(36)NK6RO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
RAV-GM902ATW-E/RAV-HM901FT-E
DI
|
TOSHIBA | Floor standing | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.00 | 3.70 | -15° | 8.00 | 6.30 | |
|
YUKF55BYOEBMO-1/YEKF55BXOEBM-R1
Grande Duct R32
|
YORK | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -15° | 15.30 | 12.50 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
U-200PZH4E8 / S-6071PF3E(3x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PF3E(4x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
MOX630U-48HFN8-QRD0W(GA)/MUE-48HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-48NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
KUE-140 DVR14/KPC-140 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MO-48N8-Q-1/MUE-42NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-Q(H)/MUE-48HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.39 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-QRD0W(GA)/MTJ-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MO-48N8-Q-1/MTJ-48NX
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
KUE-140 DVR14/KPD-140 DR15
Zen
|
KAYSUN | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-QRD0W(GA)-GR/MTJ-48HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
42QSV048D8S/38QUS048D8TX
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
42QSV048D8S/38QUS048D8S
Duct R32
|
CARRIER | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOX630U-48HFN8-Q(H)/MTJ-48HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MO-55N8-R/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
KUE-160 DTR13/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)-GR/MUE-55HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
42HY18VDS8C/38HU18VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
DC250HIDS8/AIC250HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
42QSS018D8S*/38QUS018D8S*
Ducted
|
CARRIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
RZAG140NV1 / FVA140A
RZAG
|
DAIKIN | Floor standing | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 3.94 | 13.40 | 9.52 | |||
|
RZAG140NY1 / FVA140A
RZAG
|
DAIKIN | Floor standing | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 3.94 | 13.40 | 9.52 | |||
|
MOE30U-55HFN8-RRD0W(GA)/MTI-55HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
MOE30U-55HFN8-R(GA)/MTI-55HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
KUE-160 DTR13/KPD-160 DR13
Zen
|
KAYSUN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 |