Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(20)
ATLANTIC
(4)
AUX
(12)
BOSCH
(14)
BRYANT
(0)
Buderus
(1)
CARRIER
(21)
CIAT
(13)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(63)
EQUATION
(0)
FUJI ELECTRIC
(20)
FUJITSU
(41)
Fujitsu Atlantic
(22)
GENERAL
(22)
GREE
(1)
GSS
(0)
HAIER
(75)
HEC
(0)
HEIWA
(0)
HISENSE
(8)
HITACHI
(13)
IVT
(0)
Inventor
(19)
KAYSUN
(20)
LG
(24)
MIDEA
(111)
MITSUBISHI ELECTRIC
(41)
Mitsubishi Heavy Industries
(16)
NORD
(5)
Nobu
(0)
PANASONIC
(7)
RIELLO
(13)
Rotenso
(3)
SAMSUNG
(12)
THERMOR
(7)
TOSHIBA
(12)
Viessmann
(9)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-2.5HVRC3 / RCI-2.5FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.53 | 4.18 | 4.12 | -25° | 5.60 | 5.20 | |
|
PUZ-M200YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.20 | 3.30 | -20° | 19.00 | 15.50 | |
|
RAS-3HVRC3 / RCI-3.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.41 | 4.20 | 4.35 | -25° | 7.10 | 6.00 | |
|
FDC140VSX-W/FDT140VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.14 | 2.56 | 14.00 | 15.50 | ||
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 12.40 | 4.14 | 4.14 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 12.40 | 4.14 | 4.14 | 13.40 | 9.52 | ||
|
RZAG125NV1
RZAG
|
DAIKIN | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.27 | 4.17 | 4.17 | 12.10 | 9.52 | ||
|
RZAG125NY1
RZAG
|
DAIKIN | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.27 | 4.17 | 4.17 | 12.10 | 9.52 | ||
|
RAS-2HVRC3 / RCI-2.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.08 | 4.23 | -25° | 5.00 | 5.00 | |
|
GUD35T1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.20 | -10° | 3.50 | 3.10 | ||
|
AC071RXADKG/AC071RN4DKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.27 | -20° | 7.10 | 4.50 | |
|
AC071RXADKG/AC071RN4PKG
CAC
|
SAMSUNG | Cassette | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.23 | -20° | 7.10 | 4.50 | |
|
AP105S2SK1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SQ1FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS1FB
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.60 | -10° | 9.20 | 7.50 | |
|
AP105S2SE1FA(H)/1U105S2SS2FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.10 | 3.50 | -10° | 9.20 | 7.50 | |
|
PUZ-ZM140VDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.67 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
FDC100VNX-W/FDTC50VH/FDTC50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.58 | 4.16 | 3.69 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDTC50VH/FDTC50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.58 | 4.16 | 3.69 | -20° | 10.00 | 11.20 | |
|
PUZ-ZM140VDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.67 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
MOX230-09HFN8-QRD1W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MOX230-09HFN8-Q(GA)/MFA2U-09HRFNX(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MO-09N8-Q/MFAU-09NX-1
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
U7RS-09/V7LI-09WiFiR
Console R32
|
Inventor | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
XDMX-025N-09M25/YDAX-025R-09M25**
XDMX
|
AIRWELL | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
42QZY012D8S*/38QUS012D8S*
Console
|
CARRIER | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
CC235HIDS8*/AIC235HIDS8*
Console
|
RIELLO | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
PUZ-ZM140YDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
42QZY018D8S*/38QUS018D8S*
Console
|
CARRIER | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
42HC18VDS8C*/38HU18VDS8C*
Console
|
CIAT | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
CC250HIDS8*/AIC250HIDS8*
Console
|
RIELLO | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
Vitoclima100-SICNAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Console
|
Viessmann | Console | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.59 | -10° | 4.90 | 4.20 | |
|
U-60PZ3E5A / S-60PY3E
2022
|
PANASONIC | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.61 | -15° | 6.00 | 4.60 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.28 | 4.11 | 3.50 | -10° | 20.00 | 11.40 | |
|
UUB1 U20 / CT24F NB0
UU
|
LG | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.39 | -10° | 6.80 | 4.10 | |
|
AUW60U4RJ7/ACT60UR4RJC8
Super Inverter R32
|
HISENSE | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.80 | -10° | 6.20 | 5.50 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/AUXG24KRLB
AUH**K
|
GENERAL | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RCG24KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/AUXG24KRLB
AUXG**K
|
FUJITSU | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
RZAG100NV1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RZA200D
RZA
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.16 | 4.10 | 19.00 | 11.20 | |||
|
NF50DBAHRA/1N50KEAFRA
NORD - Console
|
NORD | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.10 | 3.71 | -10° | 5.00 | 4.20 |