Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(11)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(82)
EQUATION
(0)
FUJI ELECTRIC
(17)
FUJITSU
(54)
Fujitsu Atlantic
(19)
GENERAL
(12)
GREE
(1)
GSS
(0)
HAIER
(60)
HEC
(0)
HEIWA
(0)
HISENSE
(7)
HITACHI
(14)
IVT
(0)
Inventor
(20)
KAYSUN
(1)
LG
(14)
MIDEA
(14)
MITSUBISHI ELECTRIC
(83)
Mitsubishi Heavy Industries
(77)
NORD
(0)
Nobu
(0)
PANASONIC
(7)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(15)
THERMOR
(0)
TOSHIBA
(27)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG100NV1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
FDC140VSX-W/FDF71VH/FDF71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
FDC140VSX-W/FDF71VH1/FDF71VH1
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
PUZ-ZM140VDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
RZAG125NV1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
PUZ-ZM140YDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
AUF175UR4RHPA8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.80 | -10° | 16.00 | 10.00 | |
|
RAV-GP1101AT8-E/RAV-HM1101FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.14 | 4.02 | 4.04 | -20° | 10.00 | 10.80 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOX430UL-24HFN8-QRD0W/MFYA400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.45 | -10° | 7.10 | 6.00 | |
|
PUZ-ZM71VHA2/PCA-M71KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.71 | -20° | 7.10 | 4.70 | |
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
PUZ-ZM100VDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
MFZ-KW50VG/MUFZ-KW50VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.75 | -25° | 5.00 | 4.50 | |
|
MUFZ-KW50VGHZ2/MFZ-KW50VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.70 | -25° | 5.00 | 4.50 | |
|
RAV-GP1401AT8-E1/RAV-HM1401FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.02 | 3.00 | -20° | 12.50 | 11.80 | |
|
RZAG60A / FHA60A9
RZAG
|
DAIKIN | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.40 | -20° | 6.00 | 4.60 | |
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
RAS-2.5HVRC3 / RPC-2.5FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.13 | 4.05 | 3.72 | -25° | 5.60 | 5.20 | |
|
RZAG71NV1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
RZAG71NY1 / FUA71A
RZAG
|
DAIKIN | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.02 | 4.20 | -10° | 6.80 | 4.70 | ||
|
U-100PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 4.24 | -15° | 10.00 | 10.00 | |
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
U-100PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 4.24 | -15° | 10.00 | 10.00 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
RZAG125NV1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
FDC125VNX-W/FDE125VH
VNX-W/VSX-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.20 | 2.90 | 12.50 | 11.40 | ||
|
PUZ-ZM100YDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
RZAG125NY1 / FHA125A
RZAG
|
DAIKIN | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.20 | 12.10 | 9.52 | |||
|
AUW60U4RJ7/AVT60UR4RB8
Super Inverter R32
|
HISENSE | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.80 | -10° | 6.20 | 5.50 | |
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFFN-48HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.34 | -10° | 14.10 | 11.50 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.15 | 19.00 | 11.20 | |||
|
MFZ-KW60VG/MUFZ-KW60VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MUFZ-KW60VGHZ2/MFZ-KW60VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MOE30U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.51 | -10° | 13.70 | 10.60 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.10 | 19.00 | 11.20 | |||
|
42QZL036D8S*/38QUS036D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
42HU36VDS8C/38HU36VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 | |
|
SC210HIDS8/AIC210HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 |