Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(8)
ATLANTIC
(0)
AUX
(4)
BOSCH
(3)
BRYANT
(0)
Buderus
(1)
CARRIER
(3)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(28)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(6)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(1)
GSS
(0)
HAIER
(21)
HEC
(0)
HEIWA
(0)
HISENSE
(6)
HITACHI
(0)
IVT
(0)
Inventor
(15)
KAYSUN
(4)
LG
(6)
MIDEA
(29)
MITSUBISHI ELECTRIC
(52)
Mitsubishi Heavy Industries
(49)
NORD
(1)
Nobu
(0)
PANASONIC
(0)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(7)
THERMOR
(3)
TOSHIBA
(20)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG100NV1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FVA100A
RZAG
|
DAIKIN | Floor standing | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.20 | 3.96 | -10° | 9.50 | 7.80 | |
|
FDC140VSX-W/FDF71VH/FDF71VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
FDC140VSX-W/FDF71VH1/FDF71VH1
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.20 | 3.75 | 14.00 | 14.30 | ||
|
PUZ-ZM140VDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
RZAG125NV1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
PUZ-ZM140YDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
AUF175UR4RHPA8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Floor standing | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.80 | -10° | 16.00 | 10.00 | |
|
RAV-GP1101AT8-E/RAV-HM1101FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.14 | 4.02 | 4.04 | -20° | 10.00 | 10.80 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOX430UL-24HFN8-QRD0W/MFYA400-24HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.45 | -10° | 7.10 | 6.00 | |
|
FDC140VSX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.15 | 3.22 | 14.00 | 14.30 | ||
|
FDC140VNX/FDF71VD1/FDF71VD1
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.15 | 3.22 | 14.00 | 13.00 | ||
|
PUZ-ZM100VDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
MFZ-KW50VG/MUFZ-KW50VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.75 | -25° | 5.00 | 4.50 | |
|
MUFZ-KW50VGHZ2/MFZ-KW50VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.70 | -25° | 5.00 | 4.50 | |
|
RAV-GP1401AT8-E1/RAV-HM1401FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.02 | 3.00 | -20° | 12.50 | 11.80 | |
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
PUZ-ZM100YDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFFN-48HRFN8-QRD0W(GA)
Floor Standing R32
|
MIDEA | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.34 | -10° | 14.10 | 11.50 | |
|
MFZ-KW60VG/MUFZ-KW60VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MUFZ-KW60VGHZ2/MFZ-KW60VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 3.45 | -25° | 6.10 | 4.80 | |
|
MOE30U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.51 | -10° | 13.70 | 10.60 | |
|
AC100BXPDKH/AC100BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 3.30 | -20° | 10.00 | 5.30 | |
|
FDC100VNA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
MFZ-KW25VG/MUFZ-KW25VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
U7iRS-24/V7KI-24WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
FDC100VNA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC71VNX-W/FDF71VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
FDC71VNX-W/FDF71VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.03 | 3.62 | -20° | 7.10 | 6.00 | |
|
42QFD048D8S*/38QUS048D8T*
Floor Standing
|
CARRIER | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.74 | 14.60 | 11.00 | ||
|
AUW105U4RK7/AUF105UR4RMPA8
Super Inverter R32
|
HISENSE | Floor standing | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
AUF140UR4RMPA8/AUW140U6RQ7
Turbo Inverter R32
|
HISENSE | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.54 | -10° | 13.50 | 8.50 | |
|
MOX630U-48HFN8-QRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 14.10 | 11.30 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
MOX230-09HFN8-QRD1W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MOX230-09HFN8-Q(GA)/MFA2U-09HRFNX(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 |