Filters · 5 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(37)
ATLANTIC
(18)
AUX
(32)
BOSCH
(37)
BRYANT
(6)
Buderus
(17)
CARRIER
(42)
CIAT
(13)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(96)
EQUATION
(4)
FUJI ELECTRIC
(35)
FUJITSU
(59)
Fujitsu Atlantic
(36)
GENERAL
(45)
GREE
(72)
GSS
(4)
HAIER
(222)
HEC
(5)
HEIWA
(4)
HISENSE
(153)
HITACHI
(22)
IVT
(1)
Inventor
(60)
KAYSUN
(21)
LG
(104)
MIDEA
(430)
MITSUBISHI ELECTRIC
(89)
Mitsubishi Heavy Industries
(14)
NORD
(19)
Nobu
(8)
PANASONIC
(82)
RIELLO
(15)
Rotenso
(2)
SAMSUNG
(61)
THERMOR
(34)
TOSHIBA
(51)
Viessmann
(6)
Vulcano
(16)
WESTPOINT
(7)
YORK
(15)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 | ||
|
GUD50ZD1/A-S/GUD50W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.20 | -10° | 5.30 | 3.90 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
MOD30U-36HFN8-QRD0W(GA)/MUE-36HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-Q(GA)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-QRD0W(GA)/MUE-36HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-QRD0W(GA)/MUE-36HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
FDMX-100N-09M25/YDAX-100H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MO-36N8-Q/MUE-36NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
KUE-105 DVR13/KPC-105 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MO-36N8-Q/MUE-36NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-Q(H)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
RAS-5M34G3AVG-E1/RAS-B16G3KVSG-E+RAS-B16G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
RAS-5M34G3AVG-E1/RAS-B16P2KVSG-E+RAS-B16P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOHG24KMTA/ASHG24KMTE
ASH**K
|
GENERAL | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
ROG24KMTA/RSG24KMTE
RS**K
|
FUJI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOEG24KMTA/ASEG24KMTE
ASE**K
|
FUJITSU | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
U-200PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 3.94 | 3.80 | -20° | 19.00 | 15.70 | |
|
RAV-GP801ATW-E/RAV-HM801KRTP-E
SDI
|
TOSHIBA | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.56 | 4.16 | 3.56 | -27° | 7.10 | 5.10 | |
|
SCM80ZS-W/SRK35ZSX-W/SRK50ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.20 | 4.77 | -15° | 8.00 | 6.70 | |
|
MUZ-FH50VEHZ/MSZ-FH50VE2
Powerful Heating series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 4.05 | -25° | 5.00 | 6.00 | |
|
42QHE24D8SH*/38QHE24D8SH*
Wall mounted
|
CARRIER | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
42HE24JS8C*/38HE24JS8C*
Wall mounted
|
CIAT | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
WR670HJM8*/AIR670HJM8*
Wall mounted
|
RIELLO | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 3.74 | -10° | 6.85 | 5.00 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
MXZ-4F72VF4/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
MXZ-4F72VF5/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG2/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
AOYG30KBTA4/ASYG07KMCC/ASYG22KMTB
AOY**K Multi
|
FUJITSU | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
AOHG30KBTA4/ASHG07KMCC/ASHG22KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
ROG30KBTA4/RSG07KMCC/RSG22KMTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
AOEG30KBTA4/ASEH07KMCG/ASEG22KMTE
AOE**K Multi
|
FUJITSU | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
AOYG30KBTA4/ASYG07KMCC/ASYG22KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
FDC100VNX-W/SRK100ZR-W
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
FDC100VSX-W/SRK100ZR-W
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
FDC100VSX-W/SRK100ZR-WF
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
FDC100VNX-W/SRK100ZR-WF
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.54 | 4.01 | 3.69 | -20° | 10.00 | 10.50 | |
|
AD140S2SM8FA/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM8FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
AD140S2SM9FA(H)/1U140S2SP2FA
R32 Super Match Plus - Duct
|
HAIER | Ceiling | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.06 | 3.72 | 13.40 | 11.00 | ||
|
MOX430U-24HFN8-QRD1W(GA)/MUE-24HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-QRD1W/MUE-24HRFNX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-Q1(GA)/MUE-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MO-24N8-Q-1/MUE-24NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 |