Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(47)
EQUATION
(0)
FUJI ELECTRIC
(18)
FUJITSU
(58)
Fujitsu Atlantic
(26)
GENERAL
(20)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(15)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(126)
Mitsubishi Heavy Industries
(43)
NORD
(0)
Nobu
(0)
PANASONIC
(22)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(20)
THERMOR
(0)
TOSHIBA
(70)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-ZM100VDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
FDC90VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
FDC90VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.91 | 4.24 | 4.02 | -15° | 9.00 | 6.00 | |
|
RAV-GP561ATW-E/RAV-HM561BTP-E
SDI
|
TOSHIBA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.81 | 4.27 | 3.48 | -27° | 5.00 | 3.80 | |
|
AC140BXPDNH / AC140BNPDKH
CAC HEE
|
SAMSUNG | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.80 | 4.00 | 3.44 | -20° | 13.40 | 7.80 | |
|
PUZ-SM125YKA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.68 | 4.63 | 3.60 | -15° | 12.10 | 8.50 | |
|
PUZ-ZM100YDA/PSA-M100KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PSA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.60 | 4.10 | 3.40 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM60VHA2/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA2/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
PUZ-ZM60VHA3/SEZ-M60DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.20 | 4.10 | -20° | 6.10 | 4.40 | |
|
FDC100VNA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
CU-Z25UBEA / CS-Z25UD3EAW
2017
|
PANASONIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
RAS-5HRC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.89 | 4.03 | 3.42 | -20° | 11.90 | 11.93 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
RAV-GM302ATP-E/RAV-HM301SDTY-E
DI
|
TOSHIBA | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.21 | 3.95 | -15° | 2.50 | 2.60 | |
|
RXM25R9 / FDXM25F9
RXM
|
DAIKIN | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.40 | 2.60 | |
|
RXM25R9 / FNA25A9
RXM
|
DAIKIN | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.60 | 2.80 | |
|
RAS-4HNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.96 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
PUZ-M140YKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140YKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-SM100VKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
RAV-GM562ATP-E/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.11 | 3.27 | -15° | 5.00 | 2.80 | |
|
FDC100VNX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.18 | 4.18 | -20° | 10.00 | 11.20 | |
|
RAV-GM301ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.31 | 4.54 | 4.47 | -15° | 2.50 | 2.30 | |
|
RAV-GM1602ATW-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.05 | 3.38 | -15° | 14.00 | 8.40 | |
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
RAV-GM1101ATP-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
FDC71VNP-W/FDE71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.74 | 4.32 | 3.62 | -15° | 7.10 | 5.70 | |
|
RAV-GM401ATP-E/RAV-HM401MUTP-E
DI
|
TOSHIBA | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.44 | 4.21 | -15° | 3.60 | 2.70 | |
|
FDC100VSX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.84 | 4.17 | 4.18 | -20° | 10.00 | 11.20 | |
|
RAV-GM801ATP-E/RAV-HM801UTP-E
DI
|
TOSHIBA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 4.42 | 3.62 | -15° | 6.70 | 5.10 | |
|
RAV-GP561ATW-E/RAV-HM561FT-E
SDI
|
TOSHIBA | Floor standing | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.21 | 3.39 | -27° | 5.00 | 3.80 |